Forteza two-position sensor is controlled in the Map interactive box using the function menu of the Forteza two-position sensor object.

To set up the Forteza two-position sensor object, it is recommended to use the Text display type on the map.

Find description of function menu commands of the Forteza two-position sensor object in the table.

Function menu command

Executed function

Switch mode

Sequentially switches the sensor operation modes.

The following modes are available for the Forteza sensors:

  • Duty mode displays the interference level
  • Adjustment displays the signal level
  • Thresholds displays the current threshold value

The following modes are available for the MIR sensors:

  • Duty mode displays the interference level
  • IR adjustment displays the signal level of the infrared channels

  • RB adjustment displays the signal level of the radio ray (radio beam) channels

  • Thresholds displays the current threshold value
Handle alarmsAlarm confirmation by the operator
ArmArms the sensor
SettingsOpens the sensor configuration window
DisarmDisarms the sensor
Change threshold

Sequentially switches the trigger threshold in the range from 0.25V to 1V and the 0.1V interval

Functions available in the Settings menu:

Adjusting and setting the threshold values for sensors should be performed in accordance with the manufacturer's technical documentation.


After the adjustment is made and the threshold values are set, the sensors should be switched to the duty mode and the Period of indicator updating parameter value should be set to Do not use. These actions will improve the general responsiveness of the system (see Configuring Forteza two-position sensor).


For the Format sensors, an alarm is generated only when it occurs simultaneously on the IR and RB channels.