It is possible to generate an event with the captured frame image when a photo is assigned to a user from a camera (see Assigning a photo to a user from a camera).
The account_manager.run.config file should be configured on the same computer on which you are planning to work with the Access Manager module. After you make changes to the account_manager.run.config file, it is necessary to restart ACFA PSIM. |
Add the following lines to the applicationSettings group:
<setting name="NotifyInitialPhoto" serializeAs="String"> <value>True</value> </setting> |
As a result, when a photo is assigned to a user from a camera, an event will be generated:
PERSON|id|NOTIFY_PHOTO|core_global<0>,base64<> |
where id is the identifier of the user to whom the photo is assigned, and base64 is the jpeg image in Base64 format.