The Visitors counter is better fit for producing average figures than exact values. |
We cannot guarantee correct operation of the Visitors counter with fish-eye video cameras. |
To configure the Visitors counter:
By default, the frame is compressed during the analysis to the specified size (3, default size is 1920 pixels on the larger side). In this case, the following algorithm is used:
If the resulting resolution is still greater than the specified one, then it is divided in half until it becomes less.
For example, the original video resolution is 2048*1536, the specified value is 1000. In this case, the original resolution will be halved 2 times (512*384), because after the first division, the value on the larger side of the frame will be greater than the specified value (1024>1000). |
To avoid detection errors on streams with a higher resolution, it is recommended that compression be reduced. |
By default, the detection tool outputs the Camera. Visitor access in the direction of "Entrance" and Camera. Visitor access in the direction of "Exit" events. If total footfall and visitor number control/exceeding notification is required, do the following:
Select Yes for the People indoor counter parameter (6).
Enter the current number of visitors within the area (5).
Set the threshold value for the Visitors counter; exceeding this limit will generate the corresponding event (7).
In the Preview window, set the detection area. It is divided to two sectors, #1 and #2. When an object moves from #2 to #1, the system treats it as entry; alternatively, #1 to #2 is treated as exit.
To configure the sectors, you can drag them by corners or sides.
To swap sectors, just click inside one of them.
To show/hide sectors in the Preview window, click the |
Click and specify the approximate size of a human. You can do so by dragging the corners of the rectangular area.
When specifying the size of a person, consider the Requirements for the person size in the frame. |
Configuration of the Visitors counter is now complete.