The system settings of the Virdi controller are set up as follows:

  1. From the Authentication mode drop-down list (1), select the mode of authentication and controller operation:
  2. From the Antipassback drop-down list (2), select the double-entry control mode:
  3. From the Card format 1 and Card format 2 drop-down lists (3), select the format for displaying the access cards data:
  4. Select the Enable force arming check box (4) if it is necessary to enable the forced arming of the zone, even if the zone has open doors.
  5. Select the Enable time synchronization check box (5) if it is necessary to enable the time synchronization on the Server and controller.
  6. Select the Enable end of line resistors check box (6) if it is necessary to enable the terminal resistors.
  7. Select the Enable logging (egress btn) checkbox (7) if it is necessary to log all events by clicking the EXIT buttons.
  8. Select the Enable interlocking on locks check box (8) if it is necessary to activate the dual locking of all doors.
  9. Click the Apply button (9) to apply the settings.

The system settings of the Virdi controller are set up.