To configure queue detection tool, do as follows:
Configure parameters.
Parameter | Description |
---|---|
Enable | Enable/disable detection tool. |
Current queue size report interval | Set an event transmission interval in seconds for sending data to the AxxonData report subsystem if the queue length exceeds the set limit. Zero value means no transmission of events. |
Decoder mode | Select a processing resource for decoding video streams. When you select a GPU, a stand-alone graphics card takes priority (when decoding with NVidia NVDEC chips). If there's no appropriate GPU, the decoding will use the Intel Quick Sync Video technology. Otherwise, CPU resources will be used for decoding. |
Frame processing period (msec) | Specify the time period in milliseconds between frames analyzed by the people counter within the area. The value should be within the range of 500 – 3000. The smaller the value of this parameter, the greater the CPU load. |
Frame size change | By default, the frame is compressed to 1920 pixels on the longer side. To avoid detection errors on streams with a higher resolution, it is recommended that compression be reduced. |
Human size | Set the approximate size of a human. The value should be within the range of 0.25 – 10. |
Queue size | Specify the number of people to trigger the alarm when exceeded. The value should be within the range of 2 – 20. |
Sensitivity | Specify the detection tool sensitivity in standard units from 0 to 1. The higher the sensitivity, the smaller the disturbances analyzed by the queue detection algorithm. Alternatively, the lower the sensitivity, the greater changes in scene are processed by the queue detection tool. |
The detection tool is now configured.