You can create IP devices in bulk by importing their parameters from a CSV file.
You have to disable the UAC first. |
Do the following:
Create a CSV file with devices listed as follows:
IP address, Port, Vendor, Model, Login, Password, Identifier, Object name, Latitude, Longitude, Azimuth, Archive name, Recording mode |
|
For example:
10.0.12.245, 80, Bosch, Dinion IP starlight 8000 MP, service, Admin12345!, 1441, Camera 1, 0, 0, 0, Archive AliceBlue, Always 10.0.12.246,, Bosch, Dinion IP starlight 8000 MP,,,,,,,,, 10.0.12.247, 80, Bosch, Dinion IP starlight 8000 MP,,,, Camera 3,,, Archive AliceBlue, On motion |
The vendor and model of the device must be specified exactly as in the list of supported devices. For correct display of the object name in Axxon One, the CSV file must be UTF-8 BOM or UTF-32 BOM encoded. |
using the IP Device Discovery Wizard in Axxon One.
|
The specified devices will be added to the configuration.