To create the Multiple objects detector, do the following:
By default, the detector is enabled and set to generate events when the number of objects in the detection area exceeds the value specified in the detector settings.
If necessary, you can change the detector parameters. The list of parameters is given in the table:
Parameter | Value | Description | |
---|---|---|---|
Other | |||
Enable | Yes | The detector is enabled by default. To disable the detector, select the No value | |
No | |||
Name | Multiple objects | Enter the detector name or leave the default name | |
Type | Multiple objects | Name of the detector type (non-editable field) | |
Basic settings | |||
Maximum object height | 100 | Specify the maximum object height as a percentage of the frame size for the detector to generate an event. The value must be in the range [0.05, 100]
| |
Maximum object speed | 500 | Specify the maximum object speed per second for the detector to generate an event. The value must be in the range [0, 500]
| |
Maximum object width | 100 | Specify the maximum object width as a percentage of the frame size for the detector to generate an event. The value must be in the range [0.05, 100]
| |
Minimum object height | 0.1 | Specify the minimum object height as a percentage of the frame size for the detector to generate an event. The value must be in the range [0.05, 100]
| |
Minimum object speed | 0 | Specify the minimum object speed per second for the detector to generate an event. The value must be in the range [0, 500]
| |
Minimum object width | 0.1 | Specify the minimum object width as a percentage of the frame size for the detector to generate an event. The value must be in the range [0.05, 100]
| |
Number of alarm objects | 10 | Specify the number of objects for the detector to generate an event. The value must be in the range [1, 100]. | |
Object class | All classes | Select the object class that must generate an event. The default value is All classes
| |
Vehicle | |||
Person |
By default, the entire frame is a detection area. If necessary, in the preview window, you can reduce the detection area (see Configuring a detection area) and/or set one or more skip areas (see Configuring a skip area).
|
To save the parameters of the detector, click the Apply button. To cancel the changes, click the Cancel button.
Configuration of the Multiple objects detector is complete.