To preconfigure the Bosch BIS system, do the following:
- Start the system server and make sure that the installed Access Engine and Automation Engine components are working.

- Start the Configuration Browser.

- In the Infrastructure section, go to the ACE Custom fields subsection, and then go to the Create field tab to create a new custom field.
This field is required for copying user data from Intellect to the BIS software. Intellect can also receive (import) user data from the BIS system. - In the Label field (1), enter an arbitrary name that is unique in both Intellect and the Bosch BIS system.
- From the Field type drop-down list (2) select Text field.
- Set the Visible checkbox (3) to make the field visible.
- Set the Unique checkbox (4) to enable the field check for uniqueness.
- From the Display in drop-down list (5), select Personal data header.
- Leave the rest of the fields as is.
- Click the Apply button to save settings.
The operation of the Bosch BIS version 4.8 was tested. |
The preconfiguration of the Bosch BIS system is now complete.