The Bosch BIS connection to ACFA PSIM is configured as follows:
In the Computer field (1), specify the network name of the computer with the BIS server.
In the Login field (2), enter the login for authorization on the BIS server. It is set by the BIS system administrator.
In the Password field (3), enter the password for authorization on the BIS server. It is set by the BIS system administrator.
In the Host (name or IP) field (4), explicitly specify the IP address of the computer with Axxon PSIM to which the BIS server will send events.
In the Port field (5), specify a local free port to which the BIS server will send events.
In the Field for user GUID field (6), enter a unique field name preconfigured in the BIS software, see Preconfiguration of the Bosch BIS software.
In the PIN size field (7), select the number of characters in the PIN code in the range from 3 to 6, the default value is 6.
Click the Read configuration button (8) to synchronize the hardware tree with the BIS software.
After synchronization, the hardware tree will be built, for example:
Click the Read users button (9) to import users from the BIS software, if any.
Click the Write configuration button (10) to copy users from Axxon PSIM to the BIS software.
Set the Dynamic update checkbox (11) to enable automatic update of user data in the BIS software when users are created, deleted and their parameters are changed.
Click the Apply button (12) to save settings.
The Bosch BIS connection to ACFA PSIM is now configured.