Associating AIM input with terms allows changing internal variable's term value at certain events.
Associating AIM input with terms is performed on the Apollo AIM Input object settings panel. The object is created under Apollo AIM Reader.
Associating AIM input with a term is performed as follows:
From the drop-down lists in the Operation with term, if input group select which values the term should have if the AIM input is not configured, armed, in a fault state or in an alarm (3). The following operations are available:
Operation | Description |
No operation | The value of the corresponding term does not change |
Clear term | The term is set to FALSE |
Set term | The term is set to TRUE |
Send impulse | The value of the term changes to the opposite for a short preset period |