In order to configure Vanderbilt SPC integration module, perform the following actions:
- Select the main Vanderbilt object.

- In the RCT id field, enter RCT id configured in the FlexC ATS settings of the Vanderbilt SPC panel.
- In the RCT IP field, enter IP address of the machine on which Vanderbilt module is added. It must be in the same network as Vanderbilt Panel.
- In the RCT port field, enter the port number configured in FlexC ATS settings of Vanderbilt SPC panel.
- Press the Apply button to save the settings.
- Press the
button, and from the drop-down list select Download configuration from device. - Press the Apply button.
As a result, all Vanderbilt SPC panels that are configured to connect with the machine with RTC IP address will be listed under the main Vanderbilt object.

Because Vanderbilt SPC panel connects to the Axxon One server, the server’s firewall must allow traffic from the device with the RCT IP address and RCT port. |
In order to configure the Vanderbilt SPC panel, do the following:
- Go to Panel settings under the main Vanderbilt object.

- In the Use field, select Yes to enable communication with selected Vanderbilt SPC panel.
- Enter proper Username and Password.
- Press the Apply button to save the settings.
- Go back to the main Vanderbilt object.

- Press the
button, and from the drop-down list select Download configuration from device. - Press the Apply button.
As a result, integration module will download all Vanderbilt SPC panel objects, including Areas and Sensors.