There are several types of video archives in Axxon PSIM:
To limit access for the operator to play back a particular type of the video archive, do the following:
In the Depth ___ last hours field, specify the number of hours available for viewing.
The number of the last hours of video archive available for viewing must be an integer. |
Enter the 0 value in the Depth ___ last hours field to disable access to the archive. |
If hours are counted since the last login to the system, set the Since last access checkbox. If hours must be counted since the current moment, don't set the Since last access checkbox.
If you set the Since last access checkbox and specify the number of hours available for viewing, the last hours are counted until the registration moment. If you set the Since last access checkbox but leave the Depth ___ last hours field blank, the access to the main archive playback isn't limited. |
Limiting access to the video archive playback for the operator is complete.