The settings panel of the System restart service system object is shown in the figure:

The table describes the setting parameters of the System restart service object.

 

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

The Identification number*
field

Automatically

Displays the identification number of the System restart service object in the video surveillance system with distributed architecture


Digits, letters, periods, hyphen, dash, and underscore

NA

Depends on the number of the System restart service objects in the video surveillance system with distributed architecture



2

The Name*
field

Enter the value in the field

Sets the name of the System restart service object in the video surveillance system with distributed architecture



Latin alphabet, Cyrillic, digits and service characters

System restart service

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

The Disable
checkbox

Set the checkbox

Disables the System restart service object in the system


Boolean type

Clear

Setthe System restart service object is disabled and isn't used

Clearthe System restart service object is enabled and used

4

The Computer
drop-down list

Select the value from the list

Sets the Computer parent object in the system to which the given System restart service object belongs


Names of the Computer objects registered in the system

Name of the Computer parent object

Name of the Computer parent object (you cannot edit the System restart service object remotely)

5

The AxxonSoft USB Watchdog for PSIM_Host.exe
checkbox

Set the checkbox

Activates the system of the automatic computer restart when the slave.exe. process isn't active

Boolean type

Clear

Setthe system of automatic restart is activated

Clearthe system of automatic restart isn't activated

Table of the performance monitoring of the Axxon PSIM modules

6

The Module
column

Automatically

Displays the list of the modules running on the computer

Names of the running modules

NA

Depends on the number of modules registered in the system

7

The Status, hours
column

Automatically

Displays the current state of the modules

Names of the current states of the modules

NA

  • loaded—the module runs;
  • unloaded (red field)no response from the module after the time period expires;
  • unloaded—the module is unloaded.

Note. The module's run time since the last restart is displayed in the HH:MM:SS format in the square brackets

8

The Response time, s column

Enter the value in the field

Sets the time interval in seconds while waiting for a response from the module. If there is no response after the specified time, you can restart the system

Non-negative integers

60

From 0 and above

9

The Quantity of restarts
column

Enter the value in the field

Sets the maximal quantity of restarts for the time period specified in the In time and Type of period columns

Non-negative integers

3

From 0 and above

10

The In time
column

Enter the value in the field

Sets the time period during which the maximum quantity of system restarts can be performed

Non-negative integers

1

From 0 and above

11

The Type of period
column

Select the value from the list

Names of time period units

hours

hoursthe time period is measured in hours

daysthe time period is measured in days

12

The Restart
column

Select the value from the list

Sets the type of system restart

Names of the possible restart types

none

nonerestart isn't performed

modulemodule restart is performed

coreAxxon PSIM core restart is performed

13

The Remains of restarts
column

Automatically

Displays the quantity of the remaining restarts for the time period specified in the In time and Type of period columns

Non-negative integers

NA

Depends on the maximum quantity of restarts and on the number of restarts that are performed for the current time period

14

The Memory (Mb) column

Enter the value in the field

Sets the memory consumption threshold used by the module above which it must be restarted

Non-negative integers

0

From 0 and above

*Name of the element isn't displayed in the settings panel of the given object