You can manage the Peridect+ parent object in the Map interactive window using the function menu of the Peridect+ object.

Commands to manage the Peridect+ parent object are described in the table:

Function menu commandFunction
RebootReboot the Peridect+ device
Switch to Active – Master

Control all outputs. External control isn’t possible in this mode

Switch to Active – Combined/MasterControl all system components according to the specified settings, control all outputs, and control all components with external commands
Synchronize timeWrite the current server time to all Peridect+ controllers
Switch to Active – Slave

Control all system components according to the specified settings. All components can only be controlled using external commands

Switch to Active – Combined/Slave

Control all system components according to the specified settings and control all outputs. When an external command is received, the parent object of the Peridect+ integration module switches to the Switch to Active – Slave mode. If after a certain time the reception of external commands stops, the parent object of the Peridect+ integration module switches to the Switch to Active – Master mode. This mode allows the system to remain operational when the software is turned off

The Peridect+ parent object can have the following states:

Connection established

Connection lost

Unknown

Active – Master

Active – Slave

Active – Combined/Master

Active – Combined/Slave

Service – Configuration

Service – Storing data from LCP1

Service – Storing data from LCP2

Service – Logging input values and detector values

Service – Logical links testing

Invalid license

Events that occurred after the connection to the Peridect+ parent device was broken are not recorded to the device controller after the connection is restored.