Configuration of the VI detection of crowd program module includes general settings and configuration settings: detection zone, configuration parameters, and detector characteristics.


You can specify only one detection zone. To delete a detection zone, click the After you delete a zone, save and reopen the settings, a default zone is automatically added. If you specify an incorrect zone, it is automatically replaced with a default zone after you save and reopen the settings. |


In the Occupancy field, specify as a percentage the share of the detection zone area that must be filled in order for the detector to record the beginning of the Crowd event. If the occupancy remains longer than the time threshold specified in the Reaction time (s) field, the Crowd alarm event is generated on the detector. The default value is 50.
In the Reaction time (s) field, specify in seconds the time interval after which the Crowd alarm event is generated on the detector if the value of the Occupancy parameter remains equal to or above the set threshold. If during the specified period of time the value of this parameter drops below the threshold value, then the time counting stops and the counter is reset to zero. The default value is 100.
In the Time between alarms (s) field, specify in seconds the frequency of the Crowd alarm event generation. The default value is 180.
To enable debug logging mode in the VI SDK and collect detailed information about the configuration of VI detectors, use the ViDetectorDebug=1 parameter of the HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\AxxonSoft\PSIM\DetectorExt registry key (for more details, see the registry key reference guide in Vertical solutions; for information on working with the registry, see Working with Windows OS registry). |
Configuring the VI detection of crowd program module is complete.