You can manage the object of the Peridect+ integration module in the Map and Equipment Board interface objects using the function menu of the Peridect+ object. To open the menu of the Peridect+ object, right-click the required object. Command to manage the object of the Peridect+ integration module:

Menu command

Function

Switch to Active – MasterControl all outputs. External control isn’t possible in this mode
Switch to Active – SlaveControl all system components according to the specified settings. All components can only be controlled using external commands
Switch to Active – Combined/Master

Control all system components according to the specified settings, control all outputs, and control all components with external commands

Switch to Active – Combined/SlaveControl all system components according to the specified settings and control all outputs. When an external command is received, the parent object of the Peridect+ integration module switches to the Switch to Active – Slave mode. If after a certain time the reception of external commands stops, the parent object of the Peridect+ integration module switches to the Switch to Active – Master mode. This mode allows the system to remain operational when the software is turned off
RebootReboot the Peridect+ device
Synchronize timeWrite the current server time to all Peridect+ controllers

The following states of the object of the Peridect+ integration module are possible:

Connection established

Connection lost

Unknown

Undefined mode

Active – Master

Active – Slave

Active – Combined/Master

Active – Combined/Slave

Service – Configuration

Service – Storing data from LCP1

Service – Storing data from LCP2

Service – Logging input values and detectors

Service – Logical links testing

Invalid license