You can manage the object of the Peridect+ integration module in the Map and Equipment Board interface objects using the function menu of the Peridect+ object. To display the menu of the Peridect+ object, right-click the required object. Command to manage the object of the Peridect+ integration module:
Menu command | Function |
|---|---|
| Switch to Active – Master | Control all outputs. External control isn’t possible in this mode |
| Switch to Active – Slave | Control all system components according to the specified settings. All components can only be controlled using external commands |
| Switch to Active – Combined/Master | Control all system components according to the specified settings, control all outputs, and control all components with external commands |
| Switch to Active – Combined/Slave | Control all system components according to the specified settings and control all outputs. When an external command is received, the parent object of the Peridect+ integration module switches to the Switch to Active – Slave mode. If after a certain time the reception of external commands stops, the parent object of the Peridect+ integration module switches to the Switch to Active – Master mode. This mode allows the system to remain operational when the software is turned off |
| Reboot | Reboot the Peridect+ device |
| Synchronize time | Write the current server time to all Peridect+ controllers |
The following states of the object of the Peridect+ integration module are possible:
| Connection established |
| Connection lost |
| Unknown |
| Undefined mode |
| Active – Master |
| Active – Slave |
| Active – Combined/Master |
| Active – Combined/Slave |
| Service – Configuration |
| Service – Storing data from LCP1 |
| Service – Storing data from LCP2 |
| Service – Logging input values and detectors |
| Service – Logical links testing |
| Invalid license |