Documentation for Axxon PSIM 1.0.0-1.0.1.

Previous page Next page


The Voice Message Service is used for registration of the program module, which supports transmission of voice messages over the telephone lines. This service provides automatic redial of the specified telephone numbers and playback of the audio files.

The settings panel of the Voice Message Service object is shown in the figure.

The table describes the setting parameters corresponding to the elements of the settings panel of the Voice Message Service object.

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

The Identification number*
field

Automatically

Displays the identification number of the Voice Message Service object in the video surveillance system with distributed architecture

Digits, letters, periods, hyphen, dash, and underscore

NA

Depends on the number of the Voice Message Service objects in the video surveillance system with distributed architecture

2

The Name*
field

Enter the value in the field

Sets the name of the Voice Message Service object in the video surveillance system with distributed architecture

Latin alphabet, Cyrillic, digits, and service characters

Voice Message Service

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive

Number of charactersfrom 1 to 60

3

The Disable
checkbox

Set the checkbox

Disables the Voice Message Service object in the video surveillance system with distributed architecture

Boolean type

Clear

Setthe Voice Message Service object is disabled and isn't used

Clearthe Voice Message Service object is enabled and used

4

The Computer
drop-down list

Select the value from the list

Sets the Computer parent object of the system with the distributed architecture, to which the given Voice Message Service object belongs

Names of the Computer objects registered in the system

Name of the Computer parent object

Depends on the number of the Computer objects in the video surveillance system with distributed architecture

The Settings group

5

The Modem drop-down list

Select the value from the list

Sets the voice modem used for transmitting the voice messages

Names of the voice modem registered in Windows OS

NA

Depends on the number of the connected voice modems

6

The button

Click the button

Scans connected devices to identify the voice modems and put them in the Modem list

NA

NA

NA

7

The Dialing (pulse/tone) checkbox

Set the checkbox

Sets the number dialling mode: pulse or tone

Boolean type

Clear

Settone

Clearpulse 

8

The Redial attempts field

Enter the value in the field

Sets the maximum number of redial attempts to establish a connection

Sequence of numbers

3

From 1 to 10.

Recommended from 1 to 5

9

The Pause between redial attempts field

Enter the value in the field

Sets the length of a pause between redial attempts

Sequence of numbers

5

From 3 to 600.

Recommended from 30 to 120

10

The Wait for tone signal checkbox

Set the checkbox

Enables the tone signal wait function in the phone line before dialling the number

Boolean type

Set

Setwaiting for a tone signal in the phone line before dialling the number

Clear—waiting for a tone signal in the phone line before dialling the number isn't required

*Name of the element isn't displayed in the settings panel of the given object