Go to documentation repository
The Program object is used to create specialized programs in the embedded programming environment of Axxon PSIM.
The settings panel of the Program object is shown in the figure.
Table describes the setting parameters corresponding to the elements of the settings panel of the Program object.
№
| Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | The Identification number* field | Automatically | Displays the identification number of the Program object in the video surveillance system | Digits, letters, periods, hyphen, dash, and underscore | NA | A line containing digits, letters, periods, hyphen, dash, and underscores. Depends on the number of the Program objects in the video surveillance system with distributed architecture |
2 | The Name* field | Enter the value in the field | Sets the name of the Program object | Latin alphabet, Cyrillic, digits and service characters | Program | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 |
3 | The Disable checkbox | Set the checkbox | Disables the Program object | Boolean type | Clear | Set—the Program object is disabled and isn't used Clear—the Program object is enabled and used |
4 | The Time schedule | Select the value from the list | Sets the time period during which the given program operates | Name of the time schedule registered in the system | Never |
|
The Computers group | ||||||
5 | The Select an element checkbox | Set the checkbox | Sets the computer on which the given program is executed | Boolean type | Clear | Set—the program is executed on the specified computer Clear—the program isn't executed on the specified computer |
6 | The Computer field | Automatically | Sets the computer in the local network | Computer names in the local network | Computer name in the local network | A line containing a sequence of any characters (letters, digits, service characters), case-insensitive. Number of characters—60 |
7 | The Name field | Automatically | Sets the name of the computer | Names of the Computer object registered in the system | Name of the Computer object registered in the system | A line containing a sequence of any characters (letters, digits, service characters), case-insensitive. Number of characters—60 |
Out of the group | ||||||
8 | The Filter field | Enter the value in the field | Sets to pre-filter events processed by the program | Latin alphabet, Cyrillic, digits and service characters | NA | A line containing a sequence of any characters (Latin letters, digits, service characters), case-insensitive. Number of characters—unlimited. The filter format is TYPE|ID|EVENT divided by semicolon. For example, the CAM||MD_STOP;CAM||MD_START format filters Alarm and Alarm end events from all Camera objects |
9 | The Text editor field | Enter the value in the field | Enters the text of the executed program | Latin alphabet, Cyrillic, digits and service characters | NA | A line containing a sequence of any characters (Latin letters, digits, service characters), case-insensitive. Number of characters—unlimited |
* Name of the element isn't displayed on the settings panel of this object