Documentation for ACFA PSIM

Previous page Next page


On the page:

Purpose of Axxon PSIM integration with FSA/ACS/PSS device

  • Provide user interface on the same software in the context of different security equipment subsystems.
  • Configure cause-and-effect connection between different subsystems (video surveillance, FSA, ACS, audio registration, and so on).
  • Use network capability of the software.
  • Joint marketing promotion of integrated solution by software and hardware manufacturers.

Integrated equipment

Designation in the table

Description
Functionality
Monitoring

Integration module only allows you to receive events. Control and configuration from ACFA PSIM is impossible

Monitoring, control

Integration module allows you to receive events and control objects, for example, from a map: arm/disarm alarm loops, command actuating devices, and so on. Configuration from ACFA PSIM is impossible

Monitoring, control, configuration

Integration module allows you to perform any operations (equipment configuration, control, monitoring) using ACFA PSIM

Auto configuration

Integration module allows you to read configuration from equipment and build the corresponding object tree in ACFA PSIM

Licensing

ACFAReader

Module type in ACFA Reader price list

ACFASensor

Module type in ACFA Sensor price list

ACFAFence

Module type in ACFA Fence price list

Type of integration

Low-level protocol

System developer has provided events, reactions, commands as a set of bytes for connection to the equipment, so the equipment can be directly connected to ACFA PSIM

SDK

Software Development Kit. System developer has provided an SDK, so the equipment can be directly connected to ACFA PSIM

Communication server

Driver program. System developer has provided their own driver (a software layer between AxxonSoft software and the equipment in which events, reactions, configuration commands, and status polling are embedded) for connecting the equipment. In order to connect the equipment to ACFA PSIM, you must install third-party service software and configure its interaction with ACFA PSIM. COM server and OPC server are examples of such programs

API

Application Programming Interface. System developer has provided an API for working with the equipment via the Web server embedded into the equipment, so the equipment can be directly connected to ACFA PSIM

SOFT-SOFT

System developer has provided an API to enable the use of your commands in ACFA PSIM and the ACFA PSIM commands in your software. In order to connect the equipment to ACFA PSIM, you must install the full version of the third-party software and configure its interaction with ACFA PSIM. Database synchronization is a variant of SOFT-SOFT type of integration at the level of sharing one database between two software, for example, for access to Event Viewer

Note

For SOFT-SOFT type of integration, the equipment connection interface isn't specified, ACFA PSIM isn't connected directly to the equipment, but to third-party software. We recommend you to contact the manufacturer of such software to specify the equipment connection interface.

Generic protocol

Generic protocol integration:

  • OPC and BACnet are industry standards. System developer makes OPC server or BACnet server implementation for their devices and transfers data via OPC or BACnet protocol. ACFA PSIM is a client of such servers and receives data (events, reactions, configuration commands, and so on);
  • SNMP is a network protocol, which allows monitoring of some devices;
  • Modbus is a communication protocol, which allows devices to communicate with each other, exchange data and commands. You can use it to monitor and control various devices such as sensors, actuating devices and controllers
Drivers Pack

Integration by one of the above methods via Drivers Pack. When you use this type of integration, you must install ACFA PSIM and Drivers Pack (version 3.49 and higher) to work with the equipment

Fire&Security Alarm (FSA) systems

Name of the integration module

Integrated hardware (name of devices)

Functionality

Name in the price list, licensing

Information on manufacturer

Type of integration

Hardware connection interface

ACFA PSIM version
CORTEX WinSCCORTEX Security Commander

Monitoring

Axxon PSIM Fire and Security Alarm System AxACFA Sensor License, per each zone (ACFASensor)

KORTEKS, SIA

Address: Liksnas street 7, Riga, LV-1003, Latvia
Phone: +371 67 505 603
Fax: +371 67 505 604
Email: support@cortex.lv
Website: http://cortex.eu/

SOFT-SOFT

(AxACFA)

NA

1.3
POLON ALPHA


Polon4500
Polon4900
TSR
ROP
EKS
EWK
SAL
UCS
Monitoring, controlAxxon PSIM Alarm Service (Polon), per panel

Polon-Alfa Spółka
z ograniczoną odpowiedzialnością Sp.k.

Website: http://www.polon-alfa.pl/en

Low-level protocolRS-2321.1
SatelIntegra 32 / Integra 64 / Integra 64 + / Integra 128+ / Integra 256+Monitoring, configuration, controlAxxon PSIM Intruder Alarm System (Satel), per panel

SATEL

Website: http://www.satel.pl/

Low-level protocolRS-2321.1
UniPOS

IFS 7xxx where x is the version

Monitoring, configuration, control

Axxon PSIM Alarm Service (UniPOS Conventional Series), per line

Axxon PSIM Alarm Service (UniPOS Addressable Series), per panel

UniPOS

Website: http://unipos-bg.com/

Low-level protocolRS-2321.1
Unipos7000 controller

All interactive fire control panels of the 7000 series are integrated

Monitoring, control

Axxon PSIM Fire and Security Alarm System AxACFA Sensor License, per each zone (ACFASensor)

UniPOS Inc

Sofia, Bulgaria, Mladost 1, 1 Efr. Nikola Paskalev Str., next to block 56
Phone: + 359 2 97 444 69
Website: www.unipos-bg.com
Email: office_sofia@unipos-bg.net

Low-level protocolRS-2321.4
Siemens Cerberus ECO

FC1840-A3
FDT181
FDO181
FDCI181-2
FDCIO181-2
FDCL181

Monitoring, controlAxxon PSIM Alarm Service (Siemens Cerberus ECO), per panel

Siemens

Website: https://www.siemens.com/global/en/home.html

Low-level protocolRS-2321.1
DSCDSC PC-1864Monitoring, controlAxxon PSIM Alarm Service (DSC), per panel

3301 Langstaff Road
Concord, Ontario, Canada

Website: http://www.dsc.com/

Low-level protocolRS-2321.1
Texecom

Premier Elite 12-W\12-W LINE
Premier Elite 24\24-W
Premier Elite 48\48-W
Premier Elite 88
Premier Elite 168
Premier Elite 640

Monitoring, controlAxxon PSIM Alarm Service (Texecom Premier Elite), per control panel

Texecom

Website: https://www.texe.com/

Low-level protocolEthernet, RS-2321.1

RISCO

ProSYS™ Plus Main PanelMonitoring, controlAxxon PSIM Fire Alarm Control Panel Risco ProSys, per panel

RISCO LTD

Israel, 75655 Rishon LeZion, 14 Hachoma Street
Phone: +972-3-9637777
Fax: +972-3-9616584
Email: info@riscogroup.com
Sales department: sales@riscogroup.com
Website: https://www.riscogroup.com/

Low-level protocolEthernet1.1

RISCO Panel (AxACFA)

All models of the ProSYS™ Plus Main Board seriesMonitoring, controlAxxon PSIM Fire and Security Alarm System AxACFA Sensor License, per each zone (ACFASensor)

RISCO LTD

Israel, 75655 Rishon LeZion, 14 Hachoma Street
Phone: +972-3-9637777
Fax: +972-3-9616584
Email: info@riscogroup.com
Sales department: sales@riscogroup.com
Website: https://www.riscogroup.com

Low-level protocolEthernet1.1
Honeywell Esser

FlexES Control
IQ8Control

Monitoring, control

Axxon PSIM Fire Alarm Control Panel ESSER by Honeywell, per panel

Esser by Honeywell

Website: https://www.esser-systems.com/en/index/

SDKRS232 to Essernet network by SEI module1.1
Honeywell

Honeywell IPM VISTA SUPER II 

Monitoring, control

Axxon PSIM Fire and Security Alarm System (Honeywell), per each zone (ACFASensor)

Honeywell Systems Group
Video and Access Control Solutions
Aston Fields Road
Whitehouse Industrial Estate
Runcorn
Cheshire
WA7 3DL
United Kingdom
Tel: +44 (0)8448 000 235
Fax: + 44 (0)01928 754050
Email: sales.video.uk@honeywell.com
www.security.honeywell.com

SOFT-SOFT

(AxACFA)

NA1.3
Cerberus PROCerberus PRO series panelMonitoring, controlAxxon PSIM Fire Alarm Control Panel Siemens Cerberus PRO, per panel

Siemens

Website: https://www.siemens.com/global/en/home.html

BACnet protocolTCP/IP to the control panel or SAFEDLINK subnetwork, requires at least "S3" license in control panel1.1
Senstar The Network Managers (NM)MonitoringThe Network Managers (NM), per controller

Senstar

Website: https://senstar.com

SDKEthernet1.1
RozetatechRozetatech OBELISK-1.0 Gateway Monitoring, controlAxxon PSIM Fire and Security Alarm System 50 AxACFA Sensor License, per each device (ACFASensor)

Rozetatech Co Ltd

B-1710, 2nd Woollim Lions Valley.14, Sagimakgol-ro 45beon-gil, 
Jungwon-gu, Seongnam-si, Gyeonggi-do
Phone: +82-31-736-5308 
Website: http://www.rozetatech.co.kr
Email: contactus@rozetatech.co.kr

SOFT-SOFT

(AxACFA)

NA1.1
Hikvision IP Receiver Pro

Hikvision DS-PHA48-EP

Hik IP Receiver Pro Version
V2.2.1.3Build20241029


Monitoring, controlAxxon PSIM Fire and Security Alarm System (Hikvision), per each zone (ACFASensor)

Hikvision USA

Address: 18639 Railroad Street, City of Industry, California 91748
Phone: +1-909-895-0400
Phone (toll-free): +1-866-200-6690 (USA and Canada only)
Phone: 909-612-9039 (technical support) 
Email (technical support): techsupport.usa@hikvision.com
Email (sales department): sales.usa@hikvision.com
Website: http://www.hikvision.com/en/

SOFT-SOFT

(AxACFA)

Ethernet1.4
Mavili

ML-1110.SCI
ML-1362.SCI
ML-1372.SCI
Sprvsr+ Web Plug-in Web

Monitoring, controlAxxon PSIM Fire and Security Alarm System (Mavili), per each device (ACFASensor)

Mavili Elektronik A.Ş

Şerifali Mahallesi Kutup Sokak No:27/1-2-4 Ümraniye TR-34775 İSTANBUL
Tel: +90 216 466 45 05 (pbx)
Fax: +90 216 466 45 10
Email: mavali@mavali.com.tr
Website: www.mavili.com.tr

SOFT-SOFT

(AxACFA)

 

Ethernet1.4
Protege

Protege GX version 4.3.352.7

We don't guarantee the compatibility with other versions

 

Monitoring, controlAxxon PSIM Fire and Security Alarm System (Protege), per each input (ACFASensor), per each sensor (ACFASensor), including elevator floor controller sensors and other functions

Integrated Control Technology (ICT) Ltd

4 John Glenn Avenue, Rosedale, Auckland 0632, New Zealand
E-mail: support@ict.co
Website: www.ict.co

SOFT-SOFT

(AxACFA)

 

NA1.5

Access Control Systems (ACS)

Name of the integration module

Integrated hardware (name of devices)

Functionality

Name in the price list, licensing

Information on manufacturer

Type of integration

Hardware connection interface

ACFA PSIM version
Noder

EWE4
EE12
EW2
EWE2
MD-R / W
MDK-R
IO16RS
Converter RS -> Wiegand

Monitoring, configuration, control

Axxon PSIM Access Control Service (Noder EW2/EWE2), per controller

Axxon PSIM Access Control Service (Noder for KONE DCS), per elevator group

Axxon PSIM Access Control Service (Noder EWE4), per controller

Axxon PSIM Access Control Service (Noder EE12), per controller


Low-level protocolEthernet

1.1

SigurAll Sigur access controllers, including E100, E300H, R500D4/E500D4, R500/E500, E500U/R500U, R900I/E900I, E900U/R900U, E2, E4, etc.Monitoring, configuration, controlAxxon PSIM Access Control Service (Sphinx), per access controller

Sigur

Website: https://sigur.com/en/ 

SOFT-SOFTNA1.1
SALTOCU50ENSVN
GateWay
Encoder
Monitoring, configuration, controlAxxon PSIM SALTO integration module, per IP address

SALTO Systems, S.L

Pol. Lanbarren C/ Arkotz, 9
20180 Oiartzun
Spain
Phone: +34 943 344 550
Website: http://www.saltosystems.com/

SOFT-SOFTNA1.1
ZKTeco

C3-100
C3-200
C3-400
C5 series: C5S110, C5S120, C5S140
EC10
ZKTeco InBio series
EX16

Monitoring, configuration, controlAxxon PSIM Access Control Service (ZKAccess), per door

ZKTeco

Phone: +86 755-33985019
Fax: 12 39 89 901
Website: http://zkteco.su/

SDKEthernet1.1
ZKTeco PUSH SDK

All ZKTeco access control devices that work via the PUSH SDK protocol (SpeedFace, ProFace, ELITE PASS terminals and Inbio Pro, C2-260, and so on controllers)

Monitoring, configuration, controlAxxon PSIM Access Control Service (ZK Teco), per each door (ACFAReader). Door can contain one or two readers depending on the model of an access controller. For more information, see the technical specifications of the corresponding controller

ZKTeco

Address: ZK Building, Wuhe Road, Gangtou, Bantian, Buji Town, Longgang District, Shenzhen, China
Phone: +86 755-33985019
Fax: 12 39 89 901
Website: https://www.zkteco.com/en/
Email: service@zkteco.com

SDK

(AxACFA)

Ethernet1.1

Schindler Port

Schindler elevator controllerMonitoring, configurationAxxon PSIM Access Control Service (Schindler Port), per controller

Schindler Management Ltd

Zugerstrasse 13, 6030 Ebikon, Switzerland
Phone+41 41 445 32 32
Website: https://www.schindler.com/

SDKEthernet1.1
Unicard U700 U700Monitoring, configuration, controlAxxon PSIM Access Control Service (UNICARD), per access control point

Unicard SA

Phone: 12 39 89 900
Fax: 12 39 89 901
Website: http://www.unicard.pl/

Low-level protocolEthernet1.1

KeyWatcher

KeyWatcherMonitoring, controlAxxon PSIM Electronic Key Control Service (KeyWatcher), per panel

Morse Watchmans

USA, 2 Morse Road Oxford, Connecticut 06478
Phone: 203-264-4949 Toll-free:  800-423-8256
Website: https://www.morsewatchmans.com/

Low-level protocolRS-2321.1
SafeKey

All SafeKey panel models

Monitoring, controlAxxon PSIM Electronic Key Control Service (SafeKey), per panel

SafeKey

95 04-118, Warszawa, ul. Ostrobramska
Phone: (+48) 22 225 32 10, (+48) 500 466 588
Email: info@safekey.pl
Website: http://safekey.pl/

Low-level protocolEthernet1.1

STX-1000

All STX series controllers
STX-2200

Monitoring, control
Axxon PSIM Access Control Service (STX1000), per controller

GS Software

ul. Półłanki 80 lok 402
30-740 Kraków, Poland
Phone: +48 12 444 69 36
Website: http://www.gs-software.pl/

Low-level protocolRS-232, RS-485, Ethernet1.1
SymmetryAMAG Symmetry software version 9.3.0Monitoring, controlAxxon PSIM Access Control Service (Amag Symmetry), per reader

AMAG Technology, Inc.

USA, 2205 W. 126th Street Unit B Hawthorne, CA 90250
Phone: 1-800-889-9138
Website: https://www.amag.com/

SOFT-SOFTNA1.1
Nedap AEOS

Nedap AEOS software version 3.3.2
Nedap AEOS AP7803
Nedap AEOS AP7003
Nedap AEOS AP7031

Monitoring, configuration (of users only), controlAxxon PSIM Access Control Service (Nedap AEOS Software), per door

Nedap N.V.

Parallelweg 2 7141 DC Groenlo The Netherlands
Phone: +31 544 471 111
Email: info@nedap.com
Website: https://nedap.com/

SOFT-SOFTNA1.1
Bosch BISBosch BIS software version 4.8Monitoring, configuration, control. The FSA part of Bosch BIS is fully supported via the OPC Wrapper moduleAxxon PSIM—Bosch BIS ACS integration, per connection to the BIS server 

Bosch Sicherheitssysteme GmbH

Website: https://www.boschsecurity.com

SOFT-SOFTNA1.1
SALTO (AxACFA)SALTO ProAccess SPACE version 6.9.5.2Monitoring,  controlAxxon PSIM Access Control System AxACFA Reader License, per each door (ACFAReader), per each encoder (ACFAReader)

SALTO Systems, S.L

Pol. Lanbarren C/ Arkotz, 9
20180 Oiartzun
Spain
Phone: +34 943 344 550
Website: www.saltosystems.com

SOFT-SOFT

(AxACFA)

NA1.1
AuroraKeyscan Aurora version 1.0.24.0Monitoring,  controlAxxon PSIM Access Control System AxACFA Reader License, per each reader (ACFAReader)

dormakaba Canada Inc

Address: 901 Burns St., E. Whitby, Ontario
Canada L1NOE6
Phone: 888-539-7226 
Website: https://www.dormakaba.us
Email: eadorders.ca@dormakaba.com

SOFT-SOFT

(AxACFA)

NA1.1
BioStar 2BioStar 2 software version 2.9.8Monitoring,  controlAxxon PSIM Access Control System AxACFA Reader License, per each reader (ACFAReader)

Suprema

17F Parkview Office Tower, Jeongja, Bundang, Seongnam, Gyeonggi, 463-863 Republic of Korea
Website: http://www.supremainc.com/
Phone: +82 31 783 4502

SOFT-SOFT

(AxACFA)

NA1.1
MicroEnginexPortalNet v1.5Monitoring, configuration (of users only), controlAxxon PSIM—MicroEngine ACS integration (per one door)

MicroEngine Technology Sdn Bhd

Unit 11-06, Block A, Phileo Damansara 2,
Section 16, Jalan 16/11, Off Jalan Damansara,
46350 Petaling Jaya, Selangor Darul Ehsan, Malaysia
Phone: (+603) 7954 0820
Website: https://www.microengine.net/
Email: enquiry@microengine.net

SOFT-SOFT

NA1.1
Axis (AxACFA)Axis A1001Monitoring,  controlAxxon PSIM Access Control System AxACFA Reader License, per each access point (ACFAReader)

Axis Communications AB

Emdalavägen 14
SE-223 69 Lund
Phone: +46 46 272 18 00
Fax: +46 46 13 61 30
Website: https://www.axis.com/

API

Ethernet1.1
Kaba Exos 9300

Kaba Exos 9300 version 4.3.1. 

Compatibility with other versions of the Kaba Exos 9300 software isn't guaranteed


Monitoring,  controlAxxon PSIMKaba Exos 9300 ACS integration (Kaba Exos Passage Way is licensed as ACFAReader)

dormakaba Canada Inc

Address: 901 Burns St., E. Whitby, Ontario
Canada L1NOE6
Phone: 888-539-7226 
Website: https://www.dormakaba.us
Email: eadorders.ca@dormakaba.com

SOFT-SOFT

NA1.1
AccessNet
(ABC v.2)

ABC v 1.3e
ABC v 12.3e
ABC v 13.3e
ABC ARCP

Monitoring,  controlAxxon PSIM—ABC v.2 ACS integration, (per one IP address)

FortNet (Integrator-Plus LLC)

Address: Kyiv, Yordanska str. 1, office 9
Website: http://www.ed.com.ua/
Email: ed@ed.com.ua

Low level protocol

Ethernet1.3
Hartmann Odyssey

ODYSSEY Software v. 3.1.0.73

Monitoring,  controlAxxon PSIM Access Control System AxACFA Reader License, per each door (ACFAReader).

Hartmann Controls Corp

10 Lockhart Rd, Barrie, ON L4N 9GB
Website: www.hartmann-controls.com/
Phone: +1 (877) 411-0101

SOFT-SOFT

(AxACFA)

 

NA1.3
FaceID

Bosch ARD-FR084-4BI
Bosch ARD-FR054-4BI

Monitoring, configurationAxxon PSIM Access Control System AxACFA Reader License, Per each reader (ACFAReader)

Bosch Sicherheitssysteme GmbH

Bosch Service Center
Postfach 30 02 20
70442 Stuttgart
GERMANY
Phone: +49 711 400 40990
Website: https://www.boschsecurity.com/

SOFT-SOFT

(AxACFA)

 

Ethernet1.3

Biometric ACS

Some of the models in the table below may not support biometric access control functions. Please refer to the documentation for the corresponding module for details.

Name of the integration module

Integrated hardware (name of devices)

Functionality

Name in the price list, licensing

Information on manufacturer

Type of integration

Hardware connection interface

ACFA PSIM version
Suprema 2

BioStation 2
BioStation 3
BioEntry W
FaceStation F2 (all models, with an option to receive temperature from Suprema Thermal Camera)
X-Station 2 (all models, with an option to work with QR codes)
CoreStation
BioEntry P2
XPass 2
XPass S2
Any device with SDK v.2 support

Monitoring, control, configuration via BioStar 2

Axxon PSIM Access Control Service "Suprema 2", per reader

Suprema

Website: http://www.supremainc.com/

SDKEthernet1.1
HikVision

DS-K26x and DS-K28x series controllers, where x is the number of doors supported (for example, DS-K2602, DS-K2804)
DS-KVx series panels, where x is the second part of the name of the call panel (for example, DS-KV8102-IP)
DS-K1T605x, DS-K1T606x, DS-K1T671x, DS-K5603x terminals, where x is the version
All other HikVision terminals

Monitoring, configuration, controlAxxon PSIM Access Control Service (HikVision), per reader

Hikvision USA

Website: http://www.hikvision.com/us/

SDKEthernet, RS-4851.1
MorphoAccess SIGMA LiteAll MorphoAccess SIGMA Lite series terminalsMonitoring, configuration, controlAxxon PSIM Access Control Service (Morpho Sigma Lite), per terminal

IDEMIA

2 Place Samuel de Champlain 92400Courbevoie France
Phone: +33 (0)1 73 60 20 20
Email: info@idemia.com

SDKEthernet1.1
Virdi

MCP-040 
AC series: AC-7000, AC-5100, AC-2200, AC-2100, AC-2000, AC-1100, AC-6000
UBio-X series: UBio-X Pro Lite, UBio-X Iris, UBio-X Slim, UBio-X Face, UBio-X Pro2, UBio-X Pro
FOH02

Monitoring, configuration, controlAxxon PSIM Access Control Service (Virdi), per controller

Union Community Co. Ltd

12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea 
Email:
sales@virditech.com
Website: https://www.virditech.com/

SDKEthernet1.1
Dahua

All Dahua terminal models
DHI-ASI7213X-T1, DHI-ASI7223X-A, DHI-ASI1202M, DHI-ASA4214F models were tested by AxxonSoft QA team
DHI-ASC1202B-D
Dahua DHI-ASM202 (installed with the ACS module) 

Monitoring, configuration, controlAxxon PSIM Access Control Service (Dahua), per terminal

Dahua Technology Co., Ltd.

Phone: +86 571 8768 8883
Fax: +86 571 8768 8815  
Email:
overseas@dahuatech.com
Website: https://www.dahuasecurity.com/

SDKEthernet1.1
BioSmart

UniPass
UniPass-EX
UniPass Pro
UniPass Pro 2 
Prox-E
BS 4
BioSmart KeyPass
5M-O
5M-E

PV-WM 
DCR-PV
FS-80 
PALMJET all models
PALMJET 2
PV-WTC 
BIOSMART QUASAR
BIOSMART QUASAR 7

Monitoring, configuration, controlAxxon PSIM Access Control Service (BIOSMARTbiometric identification), per controller

BioSmart LLC

Address: 194A Volgogradskaya str., Ekaterinburg, 620102, 
Phone: 8-804-333-99-63

Website: https://www.biosmart-tech.com/
Email: info@bio-smart.ru

SDKUSB, Ethernet1.1
BAS-IP

All BAS-IP panels
Bas-IP AA-14FB panel was tested by AxxonSoft QA team


Monitoring,  controlAxxon PSIM Access Control Service—BAS-IP panel integration, per panel

BAS-IP ltd.

Crown House 27 Old Gloucester Street, London, England, WC1N 3AX
Email: info@bas-ip.com
Phone: +44(20) 37697440
Website: https://bas-ip.com/

APIEthernet1.1

Perimeter Intrusion Detection systems (PIDs)

Name of the integration module

Integrated hardware (name of devices)

Functionality

Name in the price list, licensing

Information on manufacturer

Type of integration

Hardware connection interface

ACFA PSIM version
FortezaForteza-Adapter
Forteza-Controller
FM Series
Forteza series
Security Light LED series
MIR-M series
RELIEF series
MIR-B series
LIANA series
Monitoring, auto configuration, configuration, controlAxxon PSIM perimeter security system Integration with "Forteza", per COM port

"OKHRANNAYA TECHNIKA" LLC

Email: info@forteza-eu.com

Low-level protocolRS-4851.1
Optex

REDSCAN RLS-3060SH
RedBeam: RBM-60QN/100QN/200QN IP
Redwall PIE-1

Monitoring, controlAxxon PSIM Burglar Alarm Service (OPTEX), per device

OPTEX CO., LTD.

Headquarters Public Relations
Phone: +81-77-579-8000
Fax: +81-77-579-7190
Website: www.optex.net

Low-level protocolEthernet1.1
Intrepid IIPM-II, MTP-II, AIM-8, AIM-16, ROM-8, ROM-16, MicroWave 330Monitoring, control

Axxon PSIM Intruder Alarm Integration with "Intrepid MicroPoint II", "Intrepid MicroTrack II", per COM port


Southwest Microwave, Inc.

9055 South McKemy Street
Tempe, Arizona 85284 USA
Phone: (480) 783-0201
Fax: (480) 783-0401

Low-level protocolRS-2321.1
FFT

Aura SR
Aura LR
Secure point
FFT CAMS software version 3

Monitoring, controlAxxon PSIM Alarm Monitoring Service (FFT Cams), per sensor

Future Fibre Technologies Limited

10 Hartnett Close, Mulgrave
Victoria 3170 Australia
Phone: +61 3 9590 3100
Fax: +61 3 9560 8000
Website: http://www.fftsecurity.com/

SOFT-SOFTNA1.1
EL-Far

EF-1500
EF-2000RS
Elfar EF127
Elfar EF2000

Monitoring, control

EL-FAR Electronics Systems 2000 Ltd.

24 David Navon St. Moshav Magshimim, 5691000, Israel 
Email: info@elfar.co.il
Phone: +972 3 916 0531 | Fax: +972 3 916 0438
Website: https://www.elfar.co.il

Low-level protocolEthernet1.1
Vanderbilt

SPC4320x
SPC6300

Monitoring, controlAxxon PSIM Access Control Service (Vanderbilt), per controller

Vanderbilt International GmbH

Borsigstrasse 34, 65205 Wiesbaden, Germany Email: info.international@vanderbiltindustries.com
Phone: +49 721 958 81 38 | Fax: +49 721 958 81 59
Websitehttp://www.vanderbiltindustries.com/

Low-level protocolEthernet1.1
Fiber SensysAll 300 Series APUs (Alarm Processor Units)Monitoring, auto configuration, configuration, controlAxxon PSIM Intruder Alarm System (Fiber SenSys), per device

Fiber SenSys, Inc.

6175 NE Century Blvd.

Hillsboro, OR 97124 USA
Phone: +1 503.692.4430
Fax: +1 503.692.4410
Website: https://fibersensys.com/
SDKEthernet1.1
Peridect+ (AxACFA)PERIDECT-CUP+
PERIDECT-LCP+
PERIDECT-DSP+
PERIDECT-LIP+
Monitoring, controlAxxon PSIM perimeter security system Integration with "Peridect+", per each line detector (ACFAFence)

SIEZA

Address: Buštěhradská 109, Dubí, 272 03 Kladno, Czech Republic
Website: https://www.sieza.com/en/company/
Email: sieza@sieza.com 

SOFT-SOFTNA1.3

ACS/FSA combined systems

Name of the integration module

Integrated hardware (name of devices)

Functionality

Name in the price list, licensing

Information on manufacturer

Type of integration

Hardware connection interface

ACFA PSIM version
Paradox

EVO48
EVO192
ACM12
IP-150

Monitoring, configuration, controlAxxon PSIM Access Control and Fire Alarm Service (Paradox), per COM port

Paradox Security Systems

Website: http://www.paradox.com/

Low-level protocol

and SDK

RS-232, USB1.1
FoxSec

FS9000
FS7002PX (MK)
FS7011PX (MK)

Monitoring, configuration, controlAxxon PSIM Access Control and Fire Alarm Service (Foxsec), per controller

FoxSec

Website: http://www.foxsec.eu/

Low-level protocolEthernet1.1
ApolloSDK

AAN-100
AAN-32S
AAN-32N
AIM-2SL
AIM-4SL
AIO-168
ASA-72
ASP-4 (Monitoring and configuration only)

Monitoring, configuration, controlSee detailed information in the Supported hardware and licensing of the ApolloSDK integration module section, per server, per reader, per AIO-168, per ASA-72

AAM Systems

SDKRS-232, Ethernet1.1
HID

EDGE ER40
VertX: v1000, v100, v200, v300, v2000, EVO
OMNIKEY® 5321 CL SAM

Monitoring, configuration, controlAxxon PSIM Access Control Service (HID VertX/Edge), per reader

HID Glogal

Website: http://www.hidglobal.com/

SDKEthernet1.1
OnGuard 7.6Any Access Control, Fire Alarm or Intrusion Panel supported in OnGuard 7.6
OnGuard software version 7.6
Monitoring, configuration (users only), controlAxxon PSIM Access Control and Fire Alarm Service (OnGuard), per reader

LenelS2

1212 Pittsford Victor Rd
Pittsford, NY 14534
General phone: +1(866)788-5095
Website: https://www.lenel.com/

SDKEthernet, RS-2321.1
Honeywell Galaxy Dimension v.2

Galaxy GD-48
Galaxy GD-96
Galaxy GD-264
Galaxy GD-520
DCM
MAX4

Monitoring, configuration, controlAxxon PSIM Access Control and Fire Alarm Service (Honeywell Galaxy Dimension), per COM port

Honeywell Systems Group
Video and Access Control Solutions

Aston Fields Road
Whitehouse Industrial Estate
Runcorn
Cheshire
WA7 3DL
United Kingdom
Phone: +44 (0)8448 000 235
Fax: + 44 (0)01928 754050
Email: sales.video.uk@honeywell.com
Website: http://www.security.honeywell.com/

Low-level protocolRS-232, Ethernet1.1
HoneyWell WinPak 

Honeywell Pro3200

Synchronization, monitoring, partial control

Axxon PSIM Access Control and Fire Alarm Service (HoneyWell WinPak), per one reader and input. There are three price-list positions for the integration module:

  1. Axxon PSIM Access Control Service (WIN-PAK Main Object), per system – to be included on a mandatory basis, as it allows creating the WIN-PAK Main Object in ACFA PSIM tree.
  2. Axxon PSIM Access Control Service (WIN-PAK Card Reader), per reader – is included if readers are in use, the number of positions in the order shall be equal to the number of entrances.
  3. Axxon PSIM Access Control Service (WIN-PAK Input), per package – is included if alarm inputs are in use; the position allows the use of 16 inputs in ACFA PSIM, e.g. add 2 positions for 24 inputs

Honeywell Systems Group
Video and Access Control Solutions
Aston Fields Road
Whitehouse Industrial Estate
Runcorn
Cheshire
WA7 3DL
United Kingdom
Tel: +44 (0)8448 000 235
Fax: + 44 (0)01928 754050
Email: sales.video.uk@honeywell.com
Website: http://www.security.honeywell.com/

SOFT-SOFT

RS-232, RS485, Ethernet

1.1

Other systems

Name of the integration module

Integrated hardware (name of devices)

Functionality

Name in the price list, licensing

Information on manufacturer

Type of integration

Hardware connection interface

ACFA PSIM version
Satel GPRS-A

GPRS-A
GPRS-A LTE
GX Soft version 2.0.0 or higher

Monitoring, controlhttps://sale.axxonsoft.com/sale/secure/goods/goodsEdit.jsf?goodsId=274504

SATEL

80-298 Gdansk, Poland, ul. Budowlanych 66
Phone: +48 58 320-94-00
Fax: +48 58 320-94-01
Email: satel@satel.pl
Website: www.satel.pl

SOFT-SOFT

Mobile network1.3.1

Generic protocol integration modules

Name of the integration module

Functionality

Name in the price list, licensing

Type of integration

ACFA PSIM version
BACnet Server

Module can exchange and process data between ACFA PSIM and BACnet devices

Per each device (ACFASensor)

Generic protocol (BACnet)

1.5
Modbus master

Module can exchange data, receive events, and send commands via Modbus TCP or Modbus RTU protocols

Per each register (ACFASensor)

Generic protocol (Modbus)

1.5
OPC Wrapper

Module can transfer data in real time and integrate systems with different interfaces, providing centralized monitoring and process control

Per each variable (ACFASensor)

Generic protocol (OPC)

1.5
OPC UA

Module is used to connect to OPC server and can exchange data and receive events according to UA standard

Per each variable (ACFASensor)

Generic protocol (OPC)

1.5
SNMP Agent

Module can exchange data and receive events via SNMP protocol v.1, v.2, and v.3 

Per each SNMP value (ACFASensor)

Generic protocol (SNMP)

1.5

Service integration modules

Name of the integration module

Functionality

Name in the price list, licensing

ACFA PSIM version
ActiveMQ broker

Module is used to connect devices that use it for operation. Apache ActiveMQ is the most popular multiprotocol message broker with open source code, based on Java. Apache ActiveMQ translates messages from sender to receiver. It can connect multiple clients and servers and allows storing messages in a queue, rather than requiring both client and server to be available at the same time for communication. Such message brokers are often used in enterprise systems or any systems with a complex architecture

Module isn't licensed1.5
MQTT Broker

The MQTT broker integration module serves as an optional feature for ACFA PSIM integrations that use the MQTT protocol. Its presence eliminates the need to install third-party MQTT Broker applications, which simplifies the integration process and improves usability. This module doesn’t send events to any interfaces and has no control commands

Module isn't licensed1.5
Emulator ACFA

Module can perform the following actions:

  • simulate the modes and states of the FSA/ACS and PID hardware;
  • simulate the actions of the FSA/ACS and PID operator;
  • simulate triggering of hardware and/or change of hardware state to which the operator must respond


Per each:

  • virtual input (ACFASensor)
  • virtual sensor (ACFASensor),
  • virtual reader (ACFAReader)
  • virtual fence (ACFAFence)
1.5

Control readers

GeneralIntegrated hardware (name of devices)Name in the price list
 Documentation

Suprema BioMini
Suprema Realscan G10
Proxy-USB-MA
ST-CE321LR-WT
PW-Desktop BLE
Honeywell Voyager 1400g (supported through the Text reader module)
All PC/SC compatible smart card readers (for example: ACS ACR1252U)
BioSmart FS80*
Hikvision DS-K1F100-D8E*
Hikvision DS-K1F820-F*
Dahua DHI-ASM202*

* This control reader modules are installed automatically together with the corresponding ACS integration modules

Axxon PSIMcontrol reader for visitor management system

An unlimited number of control readers is also included in the Axxon PSIM Access Manager/Visitor Management System license

Systems connected by universal protocols

NameFunctionality in Axxon PSIMName in the price list, licensingUniversal protocol

MOXA cards (list of all cards that can be connected by the Moxa MX-AOPC UA Server or via SNMP is presented here).

Note. Licensing of OPC and SNMP connection differs. For OPC, the connection with the OPC Server is license-protected, while each Moxa input and output is licensed for SNMP

Connection with OPC Wrapper:

  • control relay depending on type of card;
  • receive the current state of connected sensors
Axxon PSIM OPC Wrapper module, per OPC computerOPC

Connection with SNMP Wrapper:

  • receive the current state of connected sensors
Axxon PSIM SNMP Wrapper module, per channelSNMP
Bosch FPA 1200/5000 and MAP-5000, as well as UGM2020, UEZ2000, Allegiant, VCS. etc. panels as part of a BIS subsystem. The ability to use the OPC Wrapper for other models must be checked with the manufacturer
  • monitoring, control
Axxon PSIM OPC Wrapper module, per OPC computerOPC
FSA SIEMENS Cerberus-PRO
  • receive the current state of object;
  • reset the object in its default state;
  • arm/include the object in the controlled area;
  • disarm/exclude the object from the controlled area;
  • set the object in test mode;
  • set the object in active state from quiet;
  • set the object in quiet state from active
Axxon PSIM OPC Wrapper module, per OPC computerOPC
ACS Gallagher 6000
  • receive events about passes;
  • door tampering;
  • exit by button
Axxon PSIM OPC Wrapper module, per OPC computerOPC
Schrack Seconet (OPC server by TIGER-SOFT http://www.tiger-soft.com.pl)
  • monitoring of the status of a zone or an element;
  • sending control commands to a group or an element;
  • internal acoustic off command;
  • external acoustic off command;
  • summary alarm reset command
Axxon PSIM OPC Wrapper module, per OPC computerOPC
Honeywell Esser (OPC server by TIGER-SOFT http://www.tiger-soft.com.pl)

Monitoring:

  • status of a point or a zone;
  • status of an output;
  • status of a line;
  • status of a panel;
  • status of an acoustic signaling device;
  • status of an UE.

Control:

  • connect/disconnect a point or a zone;
  • connect/disconnect an output;
  • send a command to a panel
Axxon PSIM OPC Wrapper module, per OPC computerOPC
Sterownik FSG
  • open/close of fire dumper;
  • set the angle of fire dumper;
  • receive the current state of connected devices;
  • receive states of fire dumper (open, close, damage);
  • control program that control all fire dumpers in case of damage;
  • show temperatures inside the ventilation tunnels;
  • control smoke exhaust fan
Axxon PSIM BACnet Wrapper Module, per deviceBACnet
AVTECH - Room Alert 24E- Alarm Switch

Monitoring of the following events:

  • Humidity is out-of-bounds;
  • Humidity is within borders;
  • Cabinet open;
  • Cabinet close;
  • Temp is out-of-bounds;
  • Temp is within bounds;

  • Power loss;

  • Power connected
Axxon PSIM SNMP Wrapper module, per channelSNMP
NAG SNR-ERD
  • receive status and events from controller elements, for example, temperature sensors, relay status (on, off)
Axxon PSIM SNMP Wrapper module, per channelSNMP
TFortis
  • device status poll
Axxon PSIM SNMP Wrapper module, per channelSNMP
Bostex Door Access System
  • door status monitoring;
  • door control
Axxon PSIM OPC Wrapper module, per OPC computerOPC
Teletek IRIS Addressable Fire Alarm Panel (vendor: Teletek Electronics)Get information on detector states, inputs/outputs, the panel itself, zones, and control commandsAxxon PSIM Modbus Wrapper module, per IP deviceModbus
KSPA 9030-01 automatic fire fighting systems controller (vendor: PJSC «Gazprom avtomatizatsiya»)Get information on detector statesAxxon PSIM Modbus Wrapper module, per IP deviceModbus

KZ fire fighting controller (vendor: OOO «Vega-GAZ»)

Get information on detector states, inputs/outputs, and control commandsAxxon PSIM Modbus Wrapper module, per IP deviceModbus
Schrack Seconet fire alarm stations (vendor: Schrack Seconet AG) Get information on detector statesAxxon PSIM Modbus Wrapper module, per IP deviceModbus
OptaSense perimeter intrusion detection system (vendor: OptaSense Ltd)Get information on detector statesAxxon PSIM Modbus Wrapper module, per IP deviceModbus

GPS trackers

Name of the integration module

Integrated hardware (name of devices)

Functionality

Name in the price list, licensing

Information on manufacturer

Type of integration

Hardware connection interface

ACFA PSIM version
TeltonikaAll Teltonika trackersMonitoringAxxon PSIM Geolocation Tracking System (Teltonika), per tracker

Teltonika Telematics

Saltoniskiu st. 9B-1, LT-08105, Vilnius, Lithuania
Phone: +370 5 212 7472
Website: https://teltonika-gps.com/

Low-level protocol

RS232, RS485

4G, 3G, 2G

1.1
  • No labels