Go to documentation repository
Previous page Next page
The Monitoring PSIM is installed as an extension to the Axxon PSIM software. Information about the compatibility of the Axxon PSIM software versions and Monitoring PSIM is presented in the General information about product releases and versions compatibility section.
To install Monitoring PSIM in the Server of control software configuration, do the following:
Select the MS SQL database server and specify the connection parameters. For more details, see Installation of Axxon PSIM™ as a Server/Remote Administrator's workplace. To continue the installation process, click the Next button.
Note
In the Select database Server from the drop-down list field, you must specify the 127.0.0.1 value of the IP address without using the computer names and local value. Otherwise, the Server of control software loses connection with its local database when the network cable is disconnected.
In the Database field, specify the name of the database or select it in the list of existing databases from the right and click the << button. Click the Next button.
Note
By default, the name of the database is "MonitorSSTV", and its files are stored in the SQL Server folder.
Click the Install button to start the installation process.
As a result, the system starts copying the required files of Monitoring PSIM to the computer's hard disk.
Installing the Server of control software is complete.