Documentation for Intellect 4.10.4. Documentation for other versions of Intellect is available too.

Previous page Next page


You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Next »

A cross line detector is a VMDA detector that triggers when the trajectory of an object that is in the camera coverage and crosses a virtual line.

To configure a cross line detector, do the following:

  1. Go to the settings panel for a VMDA detection object.
  2. Select a line type (straight or polyline) the crossing of which leads to a detector triggering. Only one line can be added. The first line will be deleted if there is an attempt to add a second one. 
    1. If a detector is to trigger while crossing a straight line, click the Add line button (1).
    2. If a detector is to trigger while crossing a polyline, click the Add polyline button (2).
  3. In the Video preview field ( 4), set the end point of the line, by clicking left mouse button, which crossing leads to a detector triggering.
  4. Make necessary operations with a line. Line operations are shown in the table.

    Operation

    Result

    Left mouse click in the video surveillance window

    Creation of a line’s end point

    Hover to an end point and holding the left button pressed move the mouse

    Shift of a line’s end point

    Hover to an end point and click the right mouse button

    A line’s deletion

  5. To select object type for which the detector will be enabled, click the  symbol. Available object types are:

    1.  Any object. Detector triggers when the line is crossed by any object
    2.  Man. Detector triggers when the line is crossed by a man
    3.  Vehicle. Detector triggers when the line is crossed by a vehicle
  6. By clicking the left mouse button upon one of the grey arrows, set the object’s direction across the line by which the detector will trigger. The arrow will be colored white.

    Approximate speed of detected objects when the detector triggers is displayed close to arrow. At minimal and maximal value of speed the "?" sign will display and fact of cross line regardless of speed will be detected. It is possible to change value of speed by changing arrow length moving arrowhead with pressed left mouse button.

    Note.

    Arrow has minimal length while adding.


    Note.

     It is necessary to set at least one object’s direction across the line.

    Note.

     If both directions are set, the detector will trigger at any line crossing by an object.
  7. If the alarm is to be generated when the detector triggers, set the Generate alarm on camera checkbox (5).
  8. To save the changes, click the Apply button (6).

Note.

 To clear the preview field from a visual elemnt (line), click the Clear button (3).

A cross line detector is now configured.