Go to documentation repository
Previous page Next page
The regions created in the system are used to group Axxon PSIM objects corresponding to the security hardware by its location on the protected territory.
To include hardware in the region, select the required Region from the Region list of the identification panel of the corresponding object on the Hardware tab.
Arming all cameras included in Region 1.1 when Macro 1 is run. The parameters of the macro are given in the table.
Event | Action | Parameters |
Macro is executed | The Control objects command of the Region 1.1 object is executed | Reaction type = ARM Object type = CAM |
In Axxon PSIM, you can display reports by the hardware grouped in regions.
The figures below show the configuration of the Event viewer object, which allows you to display a report on the Alarm event from any camera related to the Region 1.1 object.