The Failover service object is used to ensure the operation of the distributed system in the failover mode.

The settings panel of the Failover service object is shown in the figure.

The table describes the setting parameters corresponding to the elements of the settings panel of the Failover service object.

 

Parameter

 

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the Failover service object

Numbers, letters, periods, hyphen, dash, and underscore

NA

Depends on the number of the Failover service object in the video surveillance system with distributed architecture

2

Name*

Enter the value in the field

Sets the name of the Failover service object in the video surveillance system with distributed architecture

Latin, Cyrillic, numbers, and service characters

Failover service

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of characters—from 1 to 60

3

Disable

Set the checkbox

Disables the Failover service object in the video surveillance system with distributed architecture

Boolean typeClear

Setthe Failover service object is disabled and isn't used

Clearthe Failover service object is enabled and used

4

Monitor PC

Select the value from the list

Sets the name of the server, the state of which is monitored by the object

Names of the Computer objects registered in the system

NA

Depends on the number of the Computer objects registered in the system

5

Speed ​​of object transfer to monitoring computer (rpm)

Enter the value in the field

Sets the speed of transferring objects if the connection is lost. This setting is necessary so that the failover server sends messages at a certain speed and the receiving server has time to process them. The transfer speed must be set depending on the network speed, server bandwidth, and so on

Sequence of numbers

1000

From 0 and above

6

Wait for reconnection (s)

Enter the value in the field

Sets the time period in seconds after which the configuration will be transferred to the backup server after the loss of connection

Sequence of numbers

NA

From 0 to 65535

7Time left __ days

Automatically

Displays the period of time in days remaining to restore the configuration from the backup server to the main server and restore the license

Days

0.00

From 0.00 to 50.00

8Transfer if no pingSet the checkboxSpecifies if it is necessary to transfer the configuration without the ping from the main monitored serverBoolean typeClear

Setthe configuration is transferred if there is no ping

Clear—ping isn't taken into account when transferring the configuration

The Objects table

9

Type

Select the value from the list

Sets the object type in the configuration of the monitored server that must be transferred to the backup server in case of connection loss

Types of objects registered on the basis of the main server

NA

Depends on the configuration created on the basis of the main server

10

Number

Select the value from the list

Sets the identifier of the object of the selected type that must be transferred to the backup server in case of connection loss

Identifiers of the objects of the selected type that are present in the configuration of the monitored server

NA

Depends on the number of the objects of the selected type in the configuration of main server

11

Name

Automatically

Sets the name of the object that must be transferred to the backup server in case of connection loss

Names of the objects of the selected type that are present in the configuration of the monitored server

NA

Depends on the configuration created on the basis of the main server

12

Range

Click the button

Opens the window for the complex selection of the monitored objects

NA

NA

NA

*Name of the element isn't displayed in the settings panel of the given object.