Documentation for ACFA PSIM 1.3.

Previous page Next page

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 4 Next »

Manufacturer

AAM Systems

Office address: Kraznokazarmennaya str., 13-402
Moscow
Post address: Kraznokazarmennaya str., 14
Moscow, 111250
Tel: +7 (495) 924-2227
Fax: +7 (495) 362-7262
E-mail: aam@aamsystems.ru
www.aamsystems.ru 

Integration type

SDK

Equipment connection

RS-232, IP

Supported equipment

Equipment

Function

Features

AAN-100

Network controller

Central processor MC68311 CPU 32 bit
Memory to 8 MB
Real-time clock yes
PC connection interfaces: RS232 1 or Ethernet 1
Interfaces for connection with interface modules, security and relay panels: RS485 4 or Ethernet

AAN-32SNetwork controller

Central processor MC68311 CPU 32 bit
Memory to 2 MB
Real time clock yes
PC connection interfaces: RS232 1
Interfaces for connection with interface modules, security and relay panels: RS485 1 or Ethernet

AAN-32NNetwork controller

Central processor MC68311 CPU 32 bit
Memory to 2 MB
Real time clock yes
PC connection interfaces: Ethernet 1
Interfaces for connection with interface modules, security and relay panels: RS485 1 or Ethernet 1

AIM-2SLAccess controller

Central processor M68HC11 CPU
Memory:
Work storage RAM: 128 KB
EEPROM: 512 kb

Real time clock yes
Connection interfaces: Wiegand readers 2
Interfaces for connection with interface modules, security and relay panels: RS485 1 or Ethernet

AIM-4SLAccess controller

Central processor M68HC11 CPU
Memory:
Work storage RAM: 128 kB
EEPROM: 512 kb
Real time clock yes
Connection interfaces: Wiegand readers 4
Interfaces for connection with interface modules, security and relay panels: RS485 1 or Ethernet

AIO-168Security panelSecurity loops 16 
Relay outputs
Interfaces of connection to central controller: RS485 1 or Ethernet 1
ASA-72Status panel72 three-color LEDs
Display of alarms, malfunctions, duress, no alarms
Local confirmation of incoming signals
Local reset/check of LEDs
Sound alert for alarms or malfunctions
Support for 72 zones (security panel inputs, reader inputs, etc.)
Interface for connecting to the RS-485 controller
LED to indicate the connection to the controller
4 LEDs to indicate the connection to the controller for each AIO-8/16/168 alarm panel
Tamper sensor
Power failure sensor
Two general purpose alarm inputs

Protection

There are four positions in the price-list for one module:

Integration with Apollo (one server)

Integration with Apollo (one reader)

Integration with Apollo AIO-168

Integration with Apollo (one ASA-72)

Integration with Apollo (one server) — is an electronic guardant key protected Apollo SDK v.2 from the manufacturer site and storing serial keys of all devices. There is at least one key for system.

If hardware is connected to several servers with Axxon PSIM core then additional purchase of electronic protect keys is required for each second and next servers (Integration with Apollo (one reader). Own configuration for each electronic key — in accordance with settings in the object tree of Axxon PSIM

It is required to present all serial numbers of hardware at the time of module order.

Protection doesn't depend on number of connected senior panels (AAN-100 and\or AAN-32). Protection depends only from number of connected terminals (readers, sensor/relay, ASA-72). It requires with specifics of module sublicensing in company-manufacturer of module.

Apollo SDK v.2 software module works with AIM-*SL controllers directly. Also there is possibility to work with several AIM-*SL controllers using network controller ENI-110. 

  • No labels