Documentation for Intellect 4.10.4. Documentation for other versions of Intellect is available too.

Previous page Next page


You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

The Panel of Backup archive object is designed to register and configure the Panel of Backup archive interface object in the Intellect system, which allows the Operator configuring video data archiving.

The settings panel of the Panel of Backup archive object is shown in the figure.

 

The table describes the parameters of the settings corresponding to the elements of the settings panel of the Panel of Backup archive object.

Parameter

Method for entering the parameter

Parameter description

Symbols used

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the Panel of Backup archive.

Sequence of numbers

-

From 1 and above.

Depends on the number of Panel of Backup archive objects in the digital distributed video surveillance system

2

Name*

Enter the value in the box

Defines the name of the Panel of Backup archive object.

Latin, Cyrillic and service characters

Panel of Backup archive

A line containing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive

Number of symbols – from 1 to 60.

3

Disable

Is identified by the check mark

Defines the status of the Panel of Backup archive object.

Boolean type

Not available

Yes – the Panel of Backup archive is disabled and is not in use

No – the Panel of Backup archive is enabled and is in use.

4

Display

Is selected from the list

Defines the parent Display object of the digital distributed system, to which the given Panel of Backup archive  object refers.

Names of the Display objects registered in the system.

Name of the parent Display.

Depends on the number of Display objects in the digital distributed video surveillance system

5

Backup archive*

Is selected from the list

Defines an Backup archive, which the Operator will control with the Panel of Backup archive interface object.

Name of the Backup archive objects registered in the system.

-

Depends on the number of Backup archive objects in the digital distributed video surveillance system.

6

Fixed position

Is set with a check mark

Defines, if the user can drag the Panel of Backup archive over the screen with the mouse.

Boolean type

Not available

Yes – the Panel of Backup archive may not be dragged.

No – the Panel of Backup archive may be dragged.

7

X

Enter the value in the box

(Automatically, if the Fixed position option is checked).

Defines a coordinate in the X horizontal axis for the upper left corner of the Panel of Backup archive on the screen.

% of the screen width.

Not defined

From 0 to M*100, where M is the number of video monitors installed.

8

Y

Enter the value in the box

(Automatically, if the Fixed position option is checked).

Defines a coordinate in the Y vertical axis for the upper left corner of the Panel of Backup archive on the screen.

% of the screen height.

Not defined

From 0 to M*100, where M is the number of video monitors installed.

9

W

Enter the value in the box

(Automatically, if the Fixed position option is checked).

Defines the width of the Panel of Backup archive.

% of the screen width.

Not defined

From 0 to M*100, where M is the number of video monitors installed.

10

H

Enter the value in the box

(Automatically, if the Fixed position option is checked).

Defines the height of the Panel of Backup archive.

% of the screen width.

Not defined

From 0 to M*100, where M is the number of video monitors installed.

  • The name of the element is not displayed in the settings panel of the given object.