Documentation for Axxon PSIM 2.0. Documentation for other versions of Axxon PSIM is available too.

Previous page Next page


Additional system objects are the following.

On the Hardware tab:

  1. Audio playback card allows configuring the connected audio card with the audio output.
  2. Backup archive allows configuring the archive files backup to local and network disks, as well as to the USB storage.
  3. Backup audio archive allows configuring the backup of the archive recorded synchronously with audio.
  4. Cloud authorization allows configuring the operation of push notifications in Axxon PSIM.
  5. Control device allows configuring joysticks integrated via the Drivers Pack.
  6. Event counter allows configuring the count of required events within the set time interval.
  7. Failover service allows configuring the configuration transfer to backup servers in case of failure of the main ones.
  8. Failsafe Dashboard integration client allows configuring the collection and display of data from various objects without losses even in case of server, database, or network failures.
  9. HTTP-server allows configuring the client notification about events in Axxon PSIM using requests from the browser.
  10. IIDK Interface allows controlling system elements from the third-party software.
  11. Incident server allows configuring the storage of events that must be processed using the Incident handler.
  12. Keyboard allows configuring the special keyboard used for operational control of basic functions of Axxon PSIM interface objects.
  13. LDAP service allows configuring the import of users from the LDAP address book to the Axxon PSIM database.
  14. Mail Message Service allows configuring the email message sending to addresses of remote clients in the system.
  15. Manager of failover services allows configuring the maximum number of simultaneously running failover services.
  16. Manitou allows configuring the interaction with the Manitou security monitoring object service software.
  17. Map server allows configuring the external map source, from which the Axxon PSIM map layer gets an image for the layer background.
  18. NGP manager allows configuring the integration with Axxon One.
  19. ONVIF-Server allows configuring the transmission of the video stream from Axxon PSIM to the client via the ONVIF protocol.
  20. Operator query panel allows the user to model the interface dialog window with any static or dynamic content.
  21. RTSP Server allows configuring the transmission of both live video and the Axxon PSIM archive via the RTSP protocol.
  22. SIP-terminal allows configuring the IP telephony within the distributed system configuration.
  23. Streaming Dashboard integration client allows configuring the collection and display of various data from different objects.
  24. System restart service allows configuring the restart of Axxon PSIM modules if they aren't responding.
  25. Tag&Track allows configuring the surveillance of the PTZ camera for an object based on the tracks received by a regular camera using the Tracker object.
  26. Telegram bot allows configuring the sending of text messages, images, and geolocation to the Telegram chat when any event is received from the objects registered in the Axxon PSIM objects tree.
  27. VMDA metadata storage allows configuring the storage of object motion tracks in the camera FOV.
  28. Video.run watcher is a generator of events about the state of the video.run video module.
  29. VideoGuard integration client allows configuring the integration with the VideoGuard system.
  30. VideoGuard message filter allows saving the occurred events of the VideoGuard integration client in case of connection loss with the server.
  31. Videogate allows redistributing the video stream from system video servers to remote workstations.
  32. Voice notification service allows configuring the voice notification of alarm events in the system.
  33. Web-server 3.0 allows receiving archives, audio and video streams from cameras and their display via the web service, as well as viewing audio and video streams via the cloud
  34. Web server 2.0 allows configuring video surveillance using mobile clients.
  35. Web-server allows configuring the video surveillance via the Internet browser with the image transmission through the TCP/IP protocol.

On the Interfaces tab:

  1. Backup archive panel allows configuring the interface object for backing up archive files to another computer.
  2. Captions search allows configuring the search for captions text in the captions database.
  3. Display manager allows configuring the interface object that is used to manage video walls.
  4. External window allows configuring the window display that is external to the application system of the "Display" object.
  5. HTML Interface allows configuring the interface object for displaying web pages.
  6. Incident manager allows configuring the interface object for processing events according to the pre-configured script, automatically running macros, and generating event reports.
  7. Live sound switch allows configuring the interface object for directing the audio signal that comes from any audio source (microphone) to any sound detector (loudspeaker) for playback.
  8. NGP monitor allows configuring the interface object for viewing and controlling a video from Axxon One cameras.
  9. Operator protocol allows configuring the interface object for processing events coming from the security system objects and searching in the event archive.
  10. SIP-panel allows configuring the interface object used to work with SIP devices in Axxon PSIM.
  11. State statistics allows configuring the interface object that is used to monitor the states of the selected system objects.
  12. Telemetry control panel allows configuring the quick control of rotation, focus, and zooming for selected cameras.

On the Programming tab:

  1. Access Levels allows configuring access levels.
  2. Macro allows configuring simple interactions between the objects that don't have the functionality to perform the required tasks.
  3. Macro events allows configuring the event generation when a chain of interrelated events occurs.
  4. Objects links allows specifying the object's connection with cameras.
  5. Program allows configuring complex interrelations between objects if the Macro object doesn't offer the functionality to perform the required tasks. It is implemented as code in the embedded Axxon PSIM programming language.

    Note

    The Program object is displayed on the Programming tab only after you add the OldScript string parameter of the HKEY_LOCAL_MACHINE\SOFTWARE\AxxonSoft\PSIM\ registry key or use the tweaki.exe utility.

  6. Scripts allows configuring complex interrelations between objects if the Macro object doesn't offer the functionality to perform the required tasks. It is implemented as the JScript code.
  7. Time schedules allows specifying the time interval used in the Axxon PSIM schedule.
  8. Timers allows specifying the time moment used in the Axxon PSIM schedule.