Documentation for ACFA PSIM 1.3.

Previous page Configuring BioSmart FS80 control reader in the Axxon PSIM software  Configuring Suprema RealScan control reader Next page

Configure the Suprema BioMini control reader as follows:

  1. Connect the reader to a Server, download and install driver from the manufacturer's official web site.

    Note

    Registration on this site is required for download.
  2. Create the Suprema BioMini object based on the Computer object on the Hardware tab of the System Settings dialog box.
  3. In the Security Level drop-down list (1) select the fingerprint verification quality level:

    • Lowest (1/1000) the lowest level.

    • Low (1/10 000) low level.

    • Normal (1/100 000) average level.

    • High - (1/1 000 000) high level.

    • Highest (1/10 000 000) the highest level.

  4. Click Apply (2) to save the settings.

Note

Attention!

The module requires the 32-bit version of the Microsoft Visual C++ 2008 redistributable package to be installed. If this component is not installed in your system, use the redist/en/x86/vc90redist.exe installer provided in the ACFA PSIM installation package.

Configuring Suprema BioMini control reader is completed.

  • No labels