After you connect a text reader to the Server, it is necessary to install the driver for the particular model, for example for Honeywell Voyager 1400g, PW-Desktop BLE. The driver can be downloaded from the vendors official websites.
To configure the text reader, do the following:
- Go to the settings panel of the Text reader object, which is created on the basis of the Computer object.
- From the Input format drop-down list (1) select the input card format:
- Default − standard format for readers.
- Honeywell − format of the Honeywell two-dimensional code reader (8 characters, where the first 3 characters are the decimal value of the facility code, and the last 5 characters are the decimal value of the card code).
- In the COM-port field (2) enter the number of the COM port that is used for connecting the control reader.
- From the drop-down list (3) select the operation mode of the control reader:
- Standard settings − the reader will receive the facility and card codes as they are.
- Custom settings − custom setting for parsing facility and card codes.
- Set the Output parse details checkbox (4), if it is necessary to display the parsing of the facility code and the card code in the Event viewer.
- Click the Apply button (5).
If the custom setting for parsing facility and card codes was selected:
- Set the Full hexadecimal mode checkbox (1) if it is necessary to use the entire card number in hexadecimal notation.
- Set the Full decimal mode checkbox (2) if it is necessary to use the entire card number in decimal notation.
- In the Get bit range from card data group, set the settings for the received card data:
- Set the length in bits of the card data (3).
- Set the offset in bits of the card data (4).
- Set the Invert byte order checkbox (5), if it is necessary to invert the byte order of the card data.
- Set the Invert bit values checkbox (6) if it is necessary to invert the bits of the card data.
- Set the Add high bit checkbox (7) if it is necessary to add the high-order bit to the received data, and select the type of the high-order bit to be added from the drop-down list.
- Set the Add low bit checkbox (8) if it is necessary to add the low-order bit to the received data, and select the type of the low-order bit to be added from the drop-down list.
- In the Get card code from range group, set the settings for the received card code:
- Set the length in bits of the card code (9).
- Set the offset in bits of the card code (10).
- Set the Invert byte order checkbox on (11) if it is necessary to invert the byte order of the card code.
- Set the Invert bit order checkbox (12) if it is necessary to invert the bit order of the card code.
- In the Get facility code from range group, set the settings for the received facility code of the card:
- Set the length of the facility code in bits (13).
- Set the offset of the facility code in bits (14).
- Set the Invert byte order checkbox (15) if it is necessary to invert the byte order in the facility code.
- Set the Invert bit order checkbox (16) if it is necessary to invert the bit order of the facility code.
- In the Facility code field (17), if necessary, enter the facility code, which will be automatically assigned to all access cards.
- Click Apply (18).
The configuration of the text reader is now complete.