Go to documentation repository
Documentation for Intellect 4.11.0-4.11.3. Documentation for other versions of Intellect is available too.
Attention!
The PS-RTP Server object was excluded from Intellect since the version 4.11.3.
The PS-RTP Server enables the following functions in Intellect:
- From the third-party software, control the cameras, PTZ, relays and sensors configured in Intellect using the GB28181 protocol.
- Watch live and archived video in the third-party software.
- Depending on the user rights, limit access to the functions listed above.
Intellect acts as a subserver in the server hierarchy. If Intellect should act as a supserver, configure Connecting cameras via the GB/T28181 protocol.
Configure the PS-RTP Server as follows:
- Create the PS-RTP Server object on the basis of the Computer object in the Hardware tab of the System settings dialog box.
- The settings panel of the object is displayed in the Main tab (1) on the right of the System settings dialog box. Here the parameters of the PS-RTP Server as a subserver are set.
- From the IP drop-down list (2) select the address of the network interface via which the third-party software will access the PS-RTP Server using the GB28181 protocol.
- In the Port field (3) specify the number of the port to which the third-party software will be connected using the GB28181 protocol.
- From the Transport drop-down list (4) select a data transfer protocol: UDP or TCP.
- In the Server ID field (5) the ID of Intellect server is displayed. It is used by the third-party software to connect to the RS-RTP Server via the GB28181 protocol.
- In the from (6) and to (7) fields set the range of the RTP ports used by the module.
- Specify the list of objects the access to which should be guaranteed by the RS-RTP Server as follows:
- Go to the List of devices tab (1).
- From the Type drop-down list (2) select the type of object created in Intellect objects tree.
- From the Name drop-down list (3) select the name of the required object.
- In the Device ID field (4) the device ID is displayed. It will be used by the third-party software to control objects via the GB28181 protocol.
- Repeat steps b-d for all required devices.
- Go to the List of devices tab (1).
- Set the parameters to connect Intellect to the external supserver:
- Go to the Connection to external server tab (1).
- Set the Connect to external server checkbox (2). As a result, the external server connection parameters are available for editing.
- In the IP field (3) specify the external server IP address.
- In the Port field (4) specify the external server connection port.
- In the Transport field (5) select the transport protocol used for the external server connection.
- In the Password field (6) specify the password for external server connection.
- In the Login field (7) specify the username for the external server connection.
- In the Server ID field (8) specify the ID of the external server via the GB28181 protocol.
- To save settings click the Apply button.
- Go to the Connection to external server tab (1).
The RS-RTP Server is now configured.
Overview