The Event viewer object is used to register and configure an interface object in Axxon PSIM. The interface object is used to display text information about the specified events initialized by the video surveillance system with distributed architecture. 

The settings panel of the Event viewer object is shown in the figures below. Tables describe the setting parameters corresponding to the elements of the settings panel of the Event viewer inteface object.

The Main tab

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

The Identification number*
field

Automatically

Displays the identification number of the Event viewer object in the video surveillance system with distributed architecture

Digits, letters, periods, hyphen, dash, and underscore

NA

Depends on the number of the Event Viewer objects in the video surveillance system with distributed architecture

2

The Name*
field

Enter the value in the field

Sets the name of the Event viewer object in the video surveillance system with distributed architecture

Latin alphabet, Cyrillic, digits, and service characters

Event viewer

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

The Disable
checkbox

Set the checkbox

Disables the Event viewer object in the video surveillance system with distributed architecture

Boolean type

Clear

Setthe Event viewer object is disabled and isn't used

Clearthe Event viewer object is enabled and used

4

The Display
drop-down list

Select the value from the list

Sets the Display parent object of the system with distributed architecture to which the given Event viewer object belongs

Names of the Display objects registered in the system

Name of the Display parent object

Depends on the number of the Display objects in the video surveillance system with distributed architecture

The Settings group

5


The X field

Enter the value in the field

Sets the X coordinate in the horizontal axis for the upper left corner of the window of the Event viewer object on the screen

% of the screen width

0

From 0 to M*100, where M is the number of the installed monitors

The Y field

Enter the value in the field

Sets the Y coordinate in the vertical axis for the upper left corner of the window of the Event viewer object on the screen

% of the screen height

70

From 0 to M*100, where M is the number of the installed monitors

6

The W field

Enter the value in the field

Sets the width of the window of the Event viewer object

% of the screen width

50

From 0 to M*100, where M is the number of the installed monitors

The H field

Enter the value in the field

Sets the height of the window of the Event viewer object

% of the screen width

26

From 0 to M*100, where M is the number of the installed monitors

7

The Monitor drop-down list

Select the value from the list

Sets the number of the monitor in the system for which the coordinates are specified

Numbers of the monitors in OS

1

From 1 to 16

8

The  button

Click the button

Opens the window to set the Event viewer window size and position using the mouse

NANANA
9The Allow moving checkboxSet the checkbox

Allows the operator to change the position of the Event viewer window using the mouse

Boolean typeClear

Set—the operator can change the position of the Event viewer window

Clear—the operator cannot change the position of the Event viewer window

10The Over all windows checkboxSet the checkbox

Allows displaying the Event viewer window over all windows

Boolean typeClear

Set—the Event viewer window is displayed over all windows

Clearthe Event viewer window is displayed in the standard mode

Out of the group

11

The Show video checkbox

Set the checkbox

Allows the operator to view the events archive initialized by the event viewer as record to disk using the Event viewer window


Boolean type

Clear

Set—the operator can view the events archive using the Event viewer window

Clear—the operator cannot view the events archive using the Event viewer window

12

The Show object on map checkbox

Set the checkbox

Allows the operator to view the objects, displayed in the Event viewer window, on the map


Boolean type

Clear

Set—the operator can view the objects, displayed in the event viewer window, on the map

Clear—the operator cannot view the objects, displayed in the event viewer window, on the map

13

The Show report checkbox

Set the checkbox

Allows the operator to create a printed form of the report and print the information about all events in the event viewer over the specified period of time


Boolean type

Clear

Set—the operator can create a printed form of the report and print the information about all events in the event viewer over the specified period of time

Clearthe operator cannot creat a printed form of the report and print the information about all events in the event viewer over the specified period of time

14

The Load protocol checkbox

Set the checkbox

Determines the latest 1000 events registered by the Event viewer with the latest system start, must be downloaded with the start of Axxon PSIM

Boolean type

Clear

Setthe latest 1000 events registered by the Event viewer with the latest system start, are downloaded with the start of Axxon PSIM

Clearthe latest events registered by the Event viewer with the latest system start, aren't downloaded with the start of Axxon PSIM

15The Hide Region checkboxSet the checkboxDisables the display of the Region column in the Event viewer windowBoolean typeClear

Setthe Region column isn't displayed

Clearthe Region column is displayed

16The Hide Card checkboxSet the checkbox

Disables the display of the Card column in the Event viewer window.
See also Guide for configuring and working with the Access Manager module the Displaying card number for access events in the Event viewer section

Boolean typeClear

Setthe Card column isn't displayed

Clearthe Card column is displayed

17The Keep colored after blinking checkboxSet the checkboxSets the highlighting of the alarm messages by the selected color after the blinking stopsBoolean typeClear

Setthe alarm messages are highlighted by the selected color after the blinking stops

Clearthe alarm message isn't highlighted by the selected color after the blinking stops. It is highlighted by the color specified in the filter

The Advanced settings group
18The View days fieldEnter the value in the fieldSets the period over which the events must be displayed in the Event viewer window, if there are more than 10,000 events (or another value set for the Max.number of rows parameter). If there are fewer events, then all events are displayed regardless of the value of this parameterDays1More than 1
19The View events drop-down listSelect the value from the list

Sets the events that must be displayed in the Event viewer window

Displayed eventsall events
  • all eventsall events are displayed in the Event viewer window;
  • last eventone last event is displayed in the Event viewer window;
  • all last eventsall last events for all selected objects are displayed
20The Max.number of rows
field
Enter the value in the fieldSets the maximum number of events to display in the event viewerSequence of numbers10000From 1 to 50000
21The Background color
field

Select the value from the list or on the Select color panel

Note. Double click the field to open the Color window

Sets the background color in the Event viewer windowRGB, CMY or HSLWhiteCorresponds to the standard range of the selected color system
22The Text color field

Select the value from the list or on the Select color panel.

Note. Double click the field to open the Color window

Sets the text color in the Event viewer windowRGB, CMY or HSLBlackCorresponds to the standard range of the selected color system
23The Color of alarm messages field

Select the value from the list or on the Select color panel.

Note. Double click the field to open the Color window

Sets the color of the alarm message lines in the Event viewer window. To apply the setting, the Duration of blinking, sec parameter must be other than 0RGB, CMY or HSLRedCorresponds to the standard range of the selected color system
24The Color of info messages field

Select the value from the list or on the Select color panel.

Note. Double click the field to open the Color window

Sets the color of the information message lines in the Event viewer window. To apply the setting, the Duration of blinking, sec parameter must be other than 0RGB, CMY or HSLBlueCorresponds to the standard range of the selected color system
25The Duration of blinking, sec fieldEnter the value in the fieldSets the time of the alarm message blinking in the Event viewer windowsecondsNAMore than 0
26The Font:<current font> buttonClick the buttonSets the font of the nformation messages in the Event viewer windowStandard Windows Font dialog windowDepends on OS settingsNA

The Filters tab

ParameterMethod for setting the parameter valueParameter descriptionRepresentationDefault valueValue range
1The Name fieldEnter the value in the field

Sets the filter name in the Event viewer window


Latin alphabet, Cyrillic, and service charactersFilter 1, Filter 2, and so onDepends on the number of the created filters
2The Specify general background color buttonClick the buttonOpens the window to select the message background color in the default filterNANANA
3The Specify general text color buttonClick the buttonOpens the window to select the message text color in the default filterNANANA
4The Add events buttonClick the buttonOpens the window for bulk adding the events from the object of the selected typeNANANA
The Event filters table*
5The Computer
drop-down list
Select the value from the list

Sets the Computer object on the basis of which the objects included in the filter must be created

Names of the Computer objects registered in the system

Empty field

Depends on the number the Computer objects in the distributed video surveillance system

6

The Type
drop-down list

Select the value from the list

Sets the types of a device that must be displayed in the event viewer.

Note. If the field is blank, the Event viewer window displays all events of all objects in the system

Types of objects registered in the system

NA

Depends on the number of the device types created in the video surveillance system with distributed architecture

7

The Number
drop-down list

Select the value from the list

Sets the identification number of the device.

Note. If the field is blank, the Event viewer window displays all events of all objects of the selected type

Sequence of numbers

NA

Depends on the number of the created devices of the selected type in the video surveillance system with distributed architecture

8The Name fieldAutomaticallyDisplays the name of the device selected in the previous itemName of the objects of the selected type registered in the systemName of specified system objectDepends on the number of devices of the selected type in the video surveillance system with distributed architecture

9

The Event
drop-down list

Select the value from the list

Sets the event received from the selected devices that must be logged into the event viewer.

Note. If the field is blank, the Event viewer window displays all events received from the specified devices

Names of the event types for the selected type of devices

NA

Depends on the type of device

10

The Region
drop-down list

Select the value from the list

Sets the region. The events from the devices located in this region are displayed in the event viewer

Names of the Region elements registered in the system

NA

Depends on the number of the Region structure elements created in the video surveillance system with distributed architecture

11The Color
drop-down list
Select the value from the listSets the messages highlighting color in the Event viewer windowRGB, CMY or HSLWhiteCorresponds to the standard range of the selected color system
12The Text color drop-down listSelect the value from the listSets the messages text color in the Event viewer windowRGB, CMY or HSLBlackCorresponds to the standard range of the selected color system

*Name of the element isn't displayed in the settings panel of the given object