Go to documentation repository
Documentation for Intellect 4.10.4. Documentation for other versions of Intellect is available too.
Previous page Next page
The settings panel of the Operator protocol object is shown in the figures.
The settings panel of the Operator protocol object. The Filters tab
The settings panel of the Operator protocol object. The DB tab
The table describes the parameters of the settings corresponding to the elements of the settings panel of the Operator protocol.
№ | Parameter | Method for specifying the parameter | Parameter description | Symbol | Default value | Range of values |
The Filter tab | ||||||
1 | The Identification number field | Automatically | Shows the identification number of the Operator protocol object in the system | Sequence of numbers | - | Depends on the number of Operator protocol objects in the system |
2 | The Name field | Type-in the value in the field | Assigns the name to the Operator protocol object. | Latin, Cyrillic and service characters | Operator protocol | A line containing a sequence of any symbols (letters, digits, service, characters apart from > and < symbols), non case-sensitive Number of symbols – from 1 to 60. |
3 | The Disable checkbox | Chechbox is set | Shows the status (enabled or disabled) of the Operator protocol object in the system
| Boolean type | No | Yes – the Operator protocol object is disabled and is not in use. No – the Operator protocol object is enabled and is in use.
|
4 | The Screen dropdown list | Is selected in the list | Assigns the parent Display object , to which the given Operator protocol object refers. | Name of the Display object s registered in the system. | Name of the parent Display object | Depends on the number of the Display object s in the system. |
5
| X: | Type-in the value in the field | Sets the coordinate in the X horizontal axis for the upper left corner of the Operator protocol interface object on the screen | % of the screen width | - | From 0 to M*100, where M is the number of monitors installed. |
Y | Type-in the value in the field | Sets the coordinate in the Y vertical axis for the upper left corner of the Operator protocol interface object on the screen | % of the screen height | - | From 0 to M*100, where M is the number of monitors installed. | |
6 | W | Type-in the value in the field | Sets the window width of the Operator protocol interface object | % of the screen width | - | From 0 to M*100, where M is the number of monitors installed. |
H | Type-in the value in the field | Sets the window width of the Operator protocol interface object | % of the screen height | - | From 0 to M*100, where M is the number of monitors installed. | |
7 | The Allow moving checkbox | Chechbox is set | Allows hand shifting of the Operator protocol interface box | Boolean type | - | Yes – hand shifting is allowed. No – hand shifting is prohibited. |
8 | The Monitor dropdown list | Select in the list | Sets the system ID of the monitor for which the coordinates are set | IDs of the monitors in the OS | 1 | From 1 to 16 |
9 | The Type dropdrown list | Select in the list | Sets the type of objects which are to be displayed in the Operator protocol interface box | Available object types | - | Depends on the registered objects in the system. Only objects for which the INFORMATION or ALARM value is selected in the Messages processing column on the Events tab in the ddi.exe utility are available for selection (see The Events tab section). |
10 | The Number dropdrown list | Select in the list | Sets the number of object on which the events are to be displayed in the Operator protocol interface box | Sequence of numbers | - | Depends on the number of registered objects of the specified type |
11 | The Name dropdrown list | Automatically | Sets the name of object on which the events are to be displayed in the Operator protocol interface box | Named of registered objects in the system | - | Depends on the registered objects in the system |
12 | The Event type dropdrown list | Select in the list | Sets events displayed in the Operator protocol interface box | Available events for the selected object | - | Depends on the object type |
13 | The Request password dropdrown list | Select in the list | Defines the necessity of password to process the event | Boolean type | - | Yes – confirmation of the password is required to process the event; No – confirmation of the password is not required to process the event |
14 | The Region dropdrown list | Select in the list | Specifies the Region object corresponding to the monitored object | List of created Region objects | - | Depends on the number of created Region objects |
15 | The Parameter field | Type-in the value in the field | Sets the name of parameter the value of which is to be displayed in the Operator protocol interface box | Latin, Cyrillic and service characters | - | Depends on the parameters sent by event |
16 | The Description field | Type-in the value in the field | Type-in the short description of the specified parameter | Latin, Cyrillic and service characters | - | - |
17 | The Autoswitch chechbox | Checkbox is set | Enables auto switch to the Current events tab in the Operator protocol window when a new event occurs. | Boolean type | - | Yes – auto switch is enabled No – auto switch is disabled |
18 | The Chief’s interface dropdown list | Select in the list | Sets the Operator protocol object to which the events are to be sent after the time specified in the Wait for the operator’s response field | List of available Operator protocol objects | - | Depends on the number of created Operator protocol objects in the system |
19 | The Map dropdown list | Select in the list | Sets the Map interface object to display the monitored object | List of available Map objects in the system | - | Depends on the number of created Map objects in the system |
20 | The Wait for the operator’s response field | Type-in the value in the field | Sets the time after which the event type becomes Not processed event or the event is escalated | Minutes | 2 | 0-600 Fractional values can be specified; integer and fractional parts are point-separated. For instance, to set 2 minutes 30 seconds time period specify 2.5. |
21 | The Delay decision making for field | Type-in the value in the field
| Sets the time for which the operator can postpone the event processing | Minutes | - | 0-600 The value is not specified or 0 – the operator can not postpone the event processing. Greater than 0 – the parameter sets the time for which the operator can postpone the event processing. It is possible to specify fractional values, the separator of the integer and fractional part is a point. For example, to set a period of 2 minutes and 30 seconds 2.5 should be specified. |
22 | The New events at the end checkbox | Chechbox is set | Places the new events at the end of the current events list | - | No | Yes – a new event is placed to the end of the list No – a new event is added to the beginning of the list |
23 | The Keep events field | Type-in the value in the field | Specifies the maximum events that can be displayed simultaneously in the list of current events | Sequence of numbers | 100 | Integer that is more than 0 |
24 | The Close elsewhere checkbox | Chechbox is set | Decides whether to delete the event from other Operator protocols when it is processed in one of the Operator protocol | Boolean type | No | Yes – when the event is processed in one of the Operator protocol, it is deleted from other Operator protocols No – when the event is processed in one of the Operator protocol, it stays unprocessed in other Operator protocols |
25 | The Password for closing checkbox | Chechbox is set | Defines the necessity to enter the password to process the event | Boolean type | No | Yes – event processing is to be confirmed with a password; No – password is not required for event processing. |
The DB tab | ||||||
26 | The Server: field | Type-in the value in the field | Defines the name of DB server in which the required database is stored | Latin, Cyrillic and service characters | Name of Server used by system | - |
27 | The Folder: field | Type-in the value in the field | Sets the name of the database in which the events are to be stored | Latin, Cyrillic and service characters | Name of main database used by system | - |
28 | The User: field | Type-in the value in the field | Sets the user name for authorization in the database server | Latin, Cyrillic and service characters | - | - |
29 | The Password: field | Type-in the value in the field | Sets the password for authorization in the database server | Latin, Cyrillic and service characters | - | - |
30 | The Connection dialog button | Click the button | Opens the dialog box of database server connection | - | - | - |