Documentation for Axxon PSIM 1.0.0-1.0.1.

Previous page Events selection for transmitting to SNMP manager  Setting up the trap with SNMP-message Next page


SNMP-service implements message conversion into SNMP format. SNMP-message is a sequence of parameters, describing the event. Parameter’s name is changed by the value of this parameter in the pattern of SNMP-message with the event registration. Changing the SNMP-message is done in the following way:

  1. Go to the settings panel of SNMP trap object.
  2. Enter in the field Message’s format (%paramName1%text% paramName2%... parameters’names in the required sequence. Description of event’s main parameters is given in the table.

    Parameter’s name

    Description of parameter

    Availability in the message

    %event_action%

    Event, registered in the system

    Is determined by object’s type, for which the event may be registered

    %event_source_id%

    Object’s identification number, for which the event has been registered

    %event_source_type%

    Object’s type, for which the event has been registered

    %owner%

    Computer name, from which the message has been received

    Obligatory message’s parameters

    %time%

    Time of event’s creation

    %user_id%

    Computer’s user identification number,   from which the message has been received

    Optional message’s parameters

    %module%

    Module’s name, for which the event has been registered

    Note.

     In case when message’s format string is not set, SNMP message is formed in accordance with the pattern  %event_action%,%event_source_id%,%event_source_type%, %owner%,%user_id%,%module%.
  3. To save the changes click Apply button.

Changing the pattern of SNMP-message is completed.

Example of SNMP-message, formed in accordance with the pattern "1)%owner% 2)%module% 3)%time% 4)%event_source_id% 5)%event_source_type% 6)%user_id% 7)%event_action%" is exemplified in the figure below.