Log in
Linked Applications
Loading…
Axxonsoft Documentation
More
Spaces
Hit enter to search
Help
Online Help
Keyboard Shortcuts
Feed Builder
What’s new
Available Gadgets
About Confluence
Log in
PSIM 1.0.0-1.0.1 (english)
Pages
Blog
Go to documentation repository
Contact technical support
Search
Page tree
Loading...
Browse pages
Configure
Space tools
Documentation for
Axxon PSIM 1.0.0-1.0.1
.
Previous page
Next page
A
t
tachments (0)
Page History
Page Information
Resolved comments
View in Hierarchy
View Source
Export to PDF
Export to Word
Copy Page Hierarchy
Pages
Documentation
Skip to end of banner
Jira links
Go to start of banner
Administrator's Guide
Administrator's Guide. INTRODUCTION
Software Lifecycle Policy
General description of the Axxon PSIM software
Axxon PSIM functionality
Structure of the digital video surveillance and audio monitoring system based on Axxon PSIM™ software
Basic hardware components of the digital video surveillance system
Software
Operating system
Software kernels
Program modules
Interaction of basic modules with the Axxon PSIM kernel
Interaction of modules of other vendors with Axxon PSIM kernel
Internal video Server database
Communication environment
Axxon PSIM software package restrictions
Hashing procedure
Traffic encryption in the Axxon PSIM software
Requirements for the software and hardware platform
Requirements for base PCs
General requirements for PCs
Operating system requirements
Free disk space (video archive size) required
Defining disk space (audio archive size)
Define required disk space (size of event log database)
Define required disk space (VMDA metadata storage)
Axxon PSIM operation on virtual machines
Requirements for TCP/IP Network
Requirements for PTZ and control panels
Requirements for audio input units
Requirements for IP devices
Requirements for GSM Equipment
Requirements for voice modems
Requirements for software which is used while integrating
Requirements for anti-virus software
Requirements for BIOS configuration
Hardware requirements for Axxon PSIM and vertical solutions detection tools
Personnel skills requirements
Installing and removing Axxon PSIM software
Installing Axxon PSIM™ software
Description of Axxon PSIM™ software distribution package
Getting ready for Axxon PSIM installation
Installation of Axxon PSIM as a Server/Remote Administrator's workstation
Installation of Axxon PSIM to the Client (Workstation for monitoring)
Updating Axxon PSIM
Using the Product.msi and Redist.exe for Axxon PSIM™ software installation
Separate installation of components for Axxon PSIM operation
Updating Drivers Pack separately from the main product
Possible installation problems and their solutions
Editing/restoring Axxon PSIM
Removing Axxon PSIM™ software
Removing Axxon PSIM from the Start menu
Removing Axxon PSIM™ software from the OS Windows panel Add or Remove Apps
Removing Axxon PSIM™ software using the installation kit
Removing Axxon PSIM™ software installed as a Service
Installing Axxon PSIM software in a silent mode
Remote installation, removal and update of Axxon PSIM software
Remote installation of Axxon PSIM software
Remote update of Axxon PSIM software
Remote removal of Axxon PSIM software
Configuring Cluster Service for Axxon PSIM
Example. Consolidation of two Servers into cluster and Axxon PSIM configuration
License key
Binding the license key to computer equipment
Match search in the license key
Specifics of the Axxon PSIM operation when the object limit is exceeded
Decoding license key
Configuring system startup and shutdown
Configuration of Axxon PSIM™ software startup
Possible options for Axxon PSIM software startup
Configuring Axxon PSIM system automatic startup from Windows OS Startup
Configuring Axxon PSIM system automatic startup bypassing standard Windows OS
Configuring Axxon PSIM™ system shutdown
Working with the system settings dialog box
General information about the System settings dialog box
Startup and shutdown of the System settings dialog box
Startup of the System settings dialog box
Shutdown of the System settings dialog box
Setting procedure for system objects
Identifiers (numbers) of system objects
Axxon PSIM configuration and setup
Configuration procedure for servers, clients and remote workstations
Server settings
Server hardware and software platform
Setting up a Server
Configuring a Remote Admin Workstation
Remote Admin Workstation hardware and program platform
Remote Admin Workstation configuration
Videogate configuration
Configuring backup archive server
Configuring remote Web-server
OS settings for correct operation of Remote Admin Workstation or Server
Configuring Remote Clients (RC)
Remote Client hardware and software platform
Configuring Remote Client
OS settings for correct operation of Remote Client
Configuration of distributed architecture
General principles of designing the digital video surveillance system with distributed architecture
Configuring procedure for the distributed system
Selecting the structure of the distributed system
Synchronizing the databases of servers and remote workstations
Registration of servers, clients and remote workstations on the administering server
Configuring the interaction of distributed system components
Configuring time synchronization in the distributed system
Role-assignment in distributed system
Features of distributed system operation using NAT
Configuration of hardware
Configuring the use of 64-bit modules
Configuring video subsystem
General information on configuring video subsystem
Registrating Video Capture Devices and cameras in Axxon PSIM™ software
Configuring the video signals processing mode while using video capture cards and analog video cameras
Creating and configuring a virtual Video capture device
Configuring video archiving
Additional information on camera
Configuring video detection tools
Configuration of multistream video
Video record from computer monitor
Configuring fisheye cameras
Configuring audio subsystem
General information on configuring audio subsystem
Registration of audio cards and microphones in Axxon PSIM™ software
Configuring audio signals digitization and processing
Configuring audio signals recording
Configuring audio playback
Features of standard sound card use
Using multi-channel audio capture devices
Using IP-devices
Configuring events logging
Configuring the Event Viewer databases synchronization
General information on the Event Viewer databases synchronization
Configuring the Event Viewer database synchronization
Example of macro to start the Event Viewer databases synchronization
Configuring telemetry
Configuring operation of distributed architecture in the failover mode
General information about Failover mode
Configuring Failover service
Limiting number of failovers running simultaneously
Configuring archive synchronization of main and backup Servers
Limitations of the Failover mode
Configuring the SNMP service
SNMP service setting order
Creating the SNMP trap object
Events selection for transmitting to SNMP manager
Configuring the message conversion into SNMP format
Setting up the trap with SNMP-message
SNMP configuration for traps receiving on remote computer
Setting up and connecting the special keyboard
Setting up the Keyboard object in Axxon PSIM™ software
Settings the interpretation rules of the Special keyboard layout by Axxon PSIM program complex
Configuring the System restart service
General information on the System restart service module
Activating the hardware control of workability
Configuring the software control of workability
Getting the information on memory consumption for processes
Configuring backup archiving
Purpose and implementation of backup archiving in the Axxon PSIM software
Configuring the Backup archive module
Configuring the Backup audio archive module
Configuring the Videogate module
General information on the videogate
Order of setting up the Videogate object
Creating the Videogate object
Selecting and configuring the cameras for the Videogate module
Selecting video cameras in bulk for the Videogate module
Selecting disks for storing the archive of the Videogate module
Configuring the recording to the Videogate archive
Notification services
Setting up the Alarm Message window
Setting up the Short Message Service (SMS)
Setting up the Mail Message Service (E-mail)
Setting up the Voice Message Service (V-dial)
Setting up the Voice Notification Service
Sending messages via Telegram bot
Replicating archive from unconnected servers using the removable storage
Order of archive replication from unconnected servers
Configuring the Data replication service object
Configuring the Target objects tree for data replication
Creating the query file
Copying the archive from the Source
Restoring the archive on the Target
Configuring the Web-server module
General information about the Web-server module
Requirements for the computers of the video surveillance system
Installing Java Runtime Environment
Authorization on the Web-server home page
Starting and setting up the Web-server module
Configuring the videoserver to connect Clients via the Web-server module
Configuring the Server to connect the Clients via the Web server 2.0 module
Web-server home page template and Java applet settings
Setting up the surveillance monitor interface of the Web-server module
Setting up the display of the data for traffic estimation in the Web-server
Setting up the Web-server module to act as a gate on a different HTTP-server
Configuring the RTSP Server module
Examples of addresses to view video from RTSP Server
Counting the system events
General Information on counting the system events
Configuring the Event counter
Data output and counter control
Configuring ONVIF-Server module
General information about ONVIF-Server module
Configuring ONVIF-Server object
Configuring getting video using ONVIF-Server module
Features of embedded storage operation via ONVIF-Server
Filtering the ONVIF-Server events
Configuring ONVIF-Server module for the Multicast mode
Configuring integration with third-party systems
Configuring interaction with Manitou software
Configuring integration with VideoGuard system
Configuring BACnet integration
Configuring integration with YITU face recognition system
Configuring SIP-terminal
Configuring the Axxon PSIM's SIP server
Configuring the Axxon PSIM's SIP client
Configuring address book of SIP-terminal
Configuring special numbers of SIP-terminal
Configuring numbers of SIP-terminal
Macros for working with SIP-terminal
Selecting speaker, microphone and camera for SIP-operator
Configuring SIP trunk
Configuring a SIP-terminal for Failover service
Configuring Incident server and Incident handler
Creating the Incident server object
Creating the Incident handler object
Selecting events to display and handle
Setting the events priority
Creating and configuring the logic of event handling
Configuring the display of logic
Configuring the use of an external database
Configuration of interfaces
Axxon PSIM Software System's interface language
Installing the language
Switching languages in the Axxon PSIM Software System
Configuring the user interface
The user interface in the Axxon PSIM software
Setup procedure for the displays
Creating a Display object
Placing the interface components on the screen
Assigning the displays to the operator workstations
Examples of the user interface configuration
Configuration of video display
Configuring video display on Video Surveillance Monitor
Configuring object's panoramic view by means of the Scene object
Configuring video transmission to Remote Workstations
Configuration of audio
Configuring audio signals playback using the video monitor
Configuring audio signals playback using the Audio player object
Features of audio signals export using the video monitor
Setting up the audio signal transmission to Remote Workstations and servers
Configuring the interactive map for object state indication and controlling the objects
General information on the structure of the interactive map of the protected facility
Configuring the interactive map
Configuring the mechanism for searching and processing alarm signals on multilayer maps
Configuring the smoothing method of the Map when scaling
Configuring the number of events displayed in the Map window
Configuring the event tooltips
Configuring the order of reactions in the object menu
Enabling the frame or video request function
Selecting a Video Gate to display video on the map
Configuring the Backup archive panel object
Configuring the Operator protocol interface object
Creating the Operator protocol object
Configuring the position of the Operator protocol object
Setting up the event filter for the Operator protocol
Setting the options for handling events in the Operator protocol
Configuring the checklist
Configuring the interface of the Operator protocol
Connecting external DBs
Configuring the Event Viewer interface object
Order of configuring the Event Viewer interface object
Configuring event filters for displaying in the Event viewer
Event viewer parameters
Parameters of displaying the Event Viewer interface box
Configuring the Incident manager interface object
Creating the Incident manager object
Configuring the Incident manager position on the screen
Configuring the main parameters of the Incident manager
Configuring the events grouping in Incident manager
Configuring user rights in Incident manager
Setting up the sound switch
Creating and configuring the Live sound switch object
Using the Live sound switch object
Setting up the Captions search window
The Captions search interface object setup procedure
Selecting the captioners
Specifying the captions search parameters
Setting up the Captions search interface window displaying
Configuring HTML interface
General description of HTML interface in Axxon PSIM software
Procedure of HTML interface configuring
Creating HTML interface object and setting its position
Creating and configuring the HTML page object
Selecting start page for displaying in HTML interface
Selecting objects to track their states
Changing the displayed version of Internet Explorer
Setting up the voice notification
Setting up the voice notification using Audio player object
Setting up the voice notification using Sound notification object
Configuring the Display manager
Configuring the State statistics display
Configuring the State statistics window position on the screen
Selecting the objects to be included in State statistics and configuring the pixels number
Configuring the database connection
Configuring the interface parameters of the State statistics window
Configuring the Charts to display analog sensor readings
Setting the Charts window position on the screen
Configuring the chart display
Configuring the SIP-panel interface object
Basic settings of the SIP-panel interface object
Advanced settings of the SIP-panel interface object
Operator settings of the SIP-panel interface object
Configuration of users and permissions
Rights administration
The users' rights
User registration and removal
Registration of users' rights
Assigning the rights and password to operators for authorization in Axxon PSIM
Setting up the default user
Changing permissions assigned to Operator
CamMonitor (ActiveX) permissions
Configuration of the LDAP Service
General information about the Service LDAP module
Configuring the connection to the LDAP address book
Configuration of correspondence between address attributes and Axxon PSIM DB fields
Examples of LDAP Service configuration
Example macro for importing users from LDAP address book
Active Directory configuration
General information about Active Directory and Axxon PSIM operation
Connecting the Axxon PSIM and Active Directory users
Connecting the Axxon PSIM user permissions to Active Directory groups
Starting the Active Directory synchronization
Configuring two-factor authentication
System settings (the Programming tab)
Configuring the Security zone
Configuring internal synchronization
Viewing the Statistics of queues window
Subdivision of the protected facility into areas and regions
About areas and regions
Creating areas
Creating regions
Creating the rule of states transition
Examples of using areas and regions
Connection of objects with cameras
Creating and using time schedules
Creating and configuring Time schedules
Viewing time schedules states
Examples of time schedules usage
Creating and using macros
Creating macros
Examples of macros
Creating and using the Timer object
Creating and configuring the Timer object
Using the Timer object
Creating and configuring Macro events
Configuring the macro events
Example of macro event
Administrator's Guide. Conclusion
Appendices
Appendix 1. Interface
Description of the Main control panel Interface
Description of the System settings dialog box
Tabs panel
Objects tree
Context menu of the system object
The object settings panel
The Apply and Undo buttons
The elements of the System settings dialog box
The Architecture tab
The Hardware tab
The Interfaces tab
The Users tab
The Programming tab
Information about program
Appendix 2. Relevant information on using Windows operating system
Working with Windows OS registry
General information about Windows OS registry
Using the registry editor
Adding string parameters to the registry
Modifying the value of string parameters in Windows OS registry
Deleting parameters from the Windows OS registry
Configuring network drives visibility when UAC is enabled in Windows OS
Connecting network disks in Windows Vista and Windows 7 OS
Setting up serial (COM) ports in Windows
Working with Windows OS services for operating Axxon PSIM installed as a Service
General information on Axxon PSIM operation as a Service
Configuring the restart of the AxxonSoft Axxon PSIM Core Server service
Using network disks of Axxon PSIM installed as a Service
Starting Axxon PSIM as a Service
Disabling Axxon PSIM as a Service startup
Configuring Axxon PSIM as a Service to work with Active Directory (AD)
Updating Axxon PSIM installed as a Service
The list of TCP ports used in Axxon PSIM
Configuring Windows Firewall
Disable the Data execution prevention (DEP) function for Axxon PSIM software package
Configuring the best performance mode
Features of ElasticSearch service operation
Limiting RAM for Elasticsearch service
Running titles database update for restoration of ElasticSearch
Appendix 3. Axxon PSIM software database management
Axxon PSIM software database functions
Guidelines on Axxon PSIM system database use
Connecting the Axxon PSIM database
Viewing Axxon PSIM database
Moving Axxon PSIM configuration database to the latest version of MS SQL Server
Configuring database synchronization
Stored procedures for adding or deleting a large number of objects
Removing the events from the PROTOCOL table using SQL queries
Removing the event table from the Axxon PSIM database
Compressing the database size
Restoring the Axxon PSIM database from the Suspect mode
Appendix 4. Updating Java time zones for proper operation with archive in iOS client
Export to PDF
No labels
Overview
Content Tools
{"serverDuration": 518, "requestCorrelationId": "d9cf98a747780b58"}