Software control of workability allows restarting the module or Axxon PSIM core if there is no response from the module.
To configure the software control of workability, do the following:
- Go to the settings panel for the System restart service object.

The list of run modules on this computer is displayed automatically in the Module column (1).
- The current state of modules is automatically displayed in the Status column (2). In the square brackets the time of module working since the last restart is displayed in HH:MM:SS format.
In the Response timeout, sec, type-in the time period in seconds during which the response from the module will be waited (3).
- In the Quantity of restart field, type-in the maximum of restarts (module or Axxon PSIM core) that can be performed within the specified time period (4).
- In the In time field, type-in the new value and/or select in the Time unit dropdown list the required metric unit of period to change the value of time period during which the maximum restarts can be performed (5-6).
- In the Restart dropdown list, select the required method of restart (7).
- Select the module method, to restart module without response.
Select the core method, to restart the Axxon PSIM core without response from the module.
The remaining number of restarts within the specified time period is automatically displayed in the Remains of restarts column (8).
- In the Memory (Mb) field, enter the value of the memory threshold consumed by the module. Exceeding of this value requires the system restart (9)
- To save changes, click the Apply button (10).
The software control of workability is now configured.