Go to documentation repository
The ONVIF-Server module supports filtering of messages and events transmitted in the metadata stream according to the ONVIF standard: Topic Filter and Message Content Filter.
You can configure the correspondence of messages for Topic Filter and the Axxon PSIM events. These are the ONVIF-Server events that start with tns and tmk in the examples below on this page. Axxon PSIM will transmit only those events for which the correspondence is configured. The remaining events and messages are sent automatically according to the specification (for example, when changing the server, profile or MotionAlarm settings, etc.).
The correspondence of messages for Topic Filter and the Axxon PSIM events is configured in the following order:
From the drop-down list of the ONVIF-server event column, select the ONVIF-Server event (1). See the events description in the table at the bottom of the page.
Note
To add a row to the table, press the "down" button on the keyboard; to delete a row, use the Ctrl+Del keyboard shortcut.
In the Event parameter name column, it is necessary to specify the parameter value or the Axxon PSIM event parameter names (5). Event parameters can be found in the Debug window, and some of them are described in the Description of events and reactions of system objects section (see Guide for creating scripts (programming) ).
You can check the message and event filtering in the third-party software, for example, in the ONVIF Device Manager utility.
To do this, go to the Events or Metadata page, depending on what messages you want to see, set the filtering conditions (1) that will be displayed in the list (2), and then click Apply (3). As a result, only the events that match the filter should be displayed.
Examples of filters used in the ONVIF Device Manager utility:
Note
When the ONVIF-Server restarts, the filters are reset, and they need to be set again.
Before changing the filter in the Events section, it is necessary to click the Refresh button for the camera in ODM.
Event | Event description | Parameters | Is configuration required |
---|---|---|---|
tns1:Device/AccessControl/Accident | Access Control System incident | Name Comment Place | Yes |
tns1:Device/AccessControl/Fault | Access Control System failure | ||
tns1:Device/FireAlarm/Alarm | Fire Alarm System alarm | Category Zone Comment | Yes |
tns1:Device/FireAlarm/Fire | Fire message from Fire Alarm System | ||
tns1:Device/FireAlarm/Fault | Fire Alarm System failure | ||
tns1:Device/GasAnalysis/ConcentrationExceeded | Increased concentration of hazardous gases | Place ConcentrationLimit GasType Concentration Comment | Yes |
tns1:Device/Introscopy/LimitExceeded | Detection of metal objects and organic matter | Account Picture Result | Yes |
tns1:Device/NeutronProbing/Detect | Detection of explosives | Place ExplosiveType Location Comment | Yes |
tns1:Device/RadiationMonitoring/Detect | Increased radiation | Picture Category Measures Account | Yes |
tns1:Device/SteamDetector/Detect | Detection of vapors and trace amounts of explosives which exceed the established threshold values | Measures Picture Account | Yes |
tns1:Device/MetalDetector/Detect | Detection of metal objects which exceed the specified values. | Picture Account | Yes |
tns1:Device/VideoSurveillanceSystem/ChannelDisconnect | Video channel disconnection | Category Comment Priority | Yes |
tns1:Device/VideoSurveillanceSystem/ChannelConnect | Video channel connection | ||
tns1:Device/VideoSurveillanceSystem/RecordTurnOff | Recording turned off | ||
tns1:Device/VideoSurveillanceSystem/RecordTurnOn | Recording turned on | ||
tns1:Device/VideoSurveillanceSystem/MotionDetectorTrigger | Motion detector triggering | ||
tns1:Device/VideoSurveillanceSystem/ReadRecordRequest | Request for the record reading | ||
tns1:Device/VideoSurveillanceSystem/DeleteRecordRequest | Request for the record deletion | ||
tns1:Device/VideoSurveillanceSystem/EditDbRecordRequest | Request for the event database editing | ||
tns1:Device/VideoSurveillanceSystem/CopyDbRecordRequest | Request for the event database copying | ||
tns1:Device/VideoSurveillanceSystem/Authorization | System user authorization | ||
tns1:Device/VideoSurveillanceSystem/ServerPowerOn | Server switched on | ||
tns1:Device/VideoSurveillanceSystem/ServerPowerOff | Server switched off | ||
axn:HDDrive/axn:Fault | Hard disk error (hard disk missing) | - | No |
axn:HDDrive/axn:RecordingFault | Hard disk failure | - | No |
axn:HDDrive/axn:DriveFull | Hard disk full (if overwriting on a loop is not enabled) | - | No |
axn:VideoSurveillanceSystem/axn:ChannelDisconnect | Video camera disconnection | - | No |
axn:VideoSurveillanceSystem/axn:ChannelConnect | Video camera connection | - | No |
axn:VideoSurveillanceSystem/axn:ServerPowerOn | Any Axxon PSIM Servers switching on in a distributed architecture | - | No |
axn:VideoSurveillanceSystem/ServerPowerOff | Any Axxon PSIM Servers switching off in a distributed architecture | - | No |
tns1:VideoSource | Events with comments in Axxon PSIM format (for examples, see The Debug window) | - | No |