To set the event viewer parameters, do the following:
If it is necessary to display only one latest event or all latest events in Event Viewer interface box, select One latest or All events in the View events: list (2).
Note
Note
In the View days text field specify the time period (in days) over which the events are to be displayed in the Event Viewer interface window if there are more events than the number set in the Max.number of rows field (3). If there are less events than set in the Max.number of rows field, in the Event Viewer, events will be displayed for all days, regardless of this setting. And the events are excluded from being displayed until their number becomes equal to the Max.number of rows value. Verification of the fulfillment of this condition and exclusion of events from being displayed happens every 50 events.
If the last 1000 logged events are to be displayed in the Event Viewer interface box, then set the Load protocol checkbox (8).
Note
Note
Set the Hide Region checkbox checked if there is no need to show the Region column in the Event viewer (9).
Set the Hide Card checkbox checked if there is no need to show the Card column in the Event viewer (10). This column is in use for displaying the access card number for events coming from ACS integration modules included in ACFA PSIM subsystem. See Displaying card number for access events in the Event viewer section in Introduction into the Guide for configuring and working with the Access Manager integration module.
Note
The card code is saved in the PROTOCOL table in the param1 field of the event associated with access (for instance, ACCESS_IN).
Event viewer parameters are now set.