Go to documentation repository
The numbers of the Axxon PSIM's SIP-terminal are configured as follows:
The Subscriber column (2) lists the numbers of all devices and operators registered on the SIP-terminal, as well as special numbers.
The Name field (3) lists the names of the corresponding devices, operators, and special numbers.
In the Redirecting field (4), enter the number to which the corresponding subscriber's calls should be forwarded to. Several numbers can be specified separated with semicolon allowing the call redirection to several devices or operators. This option enables conference calls.
Important!
It is strongly not recommended to redirect subscribers to themselves, i.e. specify the same number in the Redirecting and Subscriber fields. The system may not work correctly in this case. When trying to save settings with some subscriber redirected to itself, a warning window appears:
Click No to clear the Redirecting field for affected subscribers or click Yes to continue configuration without changes.
In the Pending, sec field (5), enter the time period in seconds, during which it is necessary to wait for a response from the subscriber. If the value is not set in the field, it is defined by the CallTimeout registry key; 30 sec. by default (see Registry keys reference guide). The value greater than set by CallTimeout will not be applied, i.e. the least of Pending, sec and CallTimeout is selected as a timeout.
From the Run macro drop-down list (7), select the Macro object which should be run when calling the subscriber. See also Creating and configuring Macro events and Macros for working with SIP-terminal.
In the Calling number multicast (video) / Calling number multicast (audio) fields (8), specify the IP address for broadcasting the video stream and audio stream from the calling device in the multicast mode.
The numbers of Axxon PSIM's SIP-terminal are configured.