Go to documentation repository
Documentation for ACFA PSIM 1.3.
Note
The SADP settings of the Hikvision controller will be illustrated by an example of the Hikvision DS-K26x series controller. You can configure the SADP settings of other Hikvision controllers/terminals in the similar way.
To configure the Hikvision SADP, do as follows:
- Go to the settings panel of the Hikvision 26X object.
- Click the SADP operations
- In the Password field, enter a new password for the Hikvision controller.
- Set the Overwrite password in Core checkbox to automatically overwrite the old password in ACFA PSIM with the new one, otherwise you need to do it manually (see Network settings of the Hikvision controller/terminal).
- Set the Activate checkbox to activate the controller in case it has been reset to factory settings. The password entered on step 3 becomes the master password for the Hikvision controller.
- Set the Setup network parameters checkbox to enable changing the network settings.
- Set the DHCP checkbox to enable DHCP.
- In the IP address field, enter the new IP address of the Hikvision controller.
- In the Port field, enter a new connection port number of the Hikvision controller.
- In the Subnet mask field, specify the mask for a subnet in which the Hikvision controller will be located.
- In the Gateway field, specify the connection gateway of the Hikvision controller.
- Set the Overwrite IP settings in Core checkbox to automatically overwrite the old network settings in ACFA PSIM, otherwise you need to do it manually (see Network settings of the Hikvision controller/terminal).
- Click the OK button to save the SADP settings.
- Click the Apply controller to save the changes. button on the settings panel of the Hikvision
Overview
Content Tools