Documentation for Axxon Next 4.5.0 - 4.5.10. Documentation for other versions of Axxon Next is available too.

Previous page Notes for weekly build 4.5.8.501  Release Notes Next page

AxxonSoft releases updated version of Axxon Next 4.5.10 bringing a number of new features and improvements.

New features in build 4.5.10.594:

A number of improvements were made to increase the stability of the system.

New features in Axxon Next 4.5.10:

  1. When installing Axxon Next, you can now specify a folder for storing log and metadata databases . When you upgrade from previous versions, you will be prompted to transfer the log and metadata databases from the system disk, as it is recommended to store them on a separate physical disk
  2. The macro for recording to the archive now works even if there is no connection to the database.
  3. The Self-diagnostics Service can now control the free space on the system disk.
  4. Redesigned the log rotation mechanism: now the log files size is checked once per hour, not once per day.
  5. Web server temporary files are now located in the log and metadata database folder, not the system disk.
  6. Added Self-diagnostics Service when installing Axxon Next on Linux.
  7. Collection of Self-diagnostics Service metrics is now enabled by default in the Support utility for information collection.
  8. Supported the VL face detection tools (including real-time face recognition).
  9. In cyclic macros to enable or disable component, you can now select all cameras in a group, not just a specific camera
  10. POS devices can now record titles to the database with a time offset
  11. Included a new version of Arpagent for working with the AxxonData cloud in a build.
  12. Included a new version of Web Client in a build.


Bug fixes in Axxon Next 4.5.10:

  1. Improved archive stability.
  2. Improved Web server stability.
  3. Fixed an issue due to which a request for video via an RTSP server did not work if it was sent to one server in the domain, and the camera was located on another one.
  4. Fixed an issue with HTTP request for archive size archive/statistics/capacity/.
  5. Fixed an issue with increase of MonitorContainer.log, EventDatabase.log, Postgresql.log files size.
  6. Fixed clearing of old events (older than 7 days) in the PostgreSQL database if less than 15 GB of free space is left on the disk with the database.
  7. Fixed rotation/archiving of logs and dumps in the Log Management Utility.
  8. Fixed a rare issue due to which the supervisor in a failover system would not update via the Web interface.
  9. Fixed search by LP numbers using special characters.
  10. Fixed a rare video export issue with "no data to export" error.
  11. Fixed export of videos from an imported archive.
  12. Fixed a rare issue due to which cameras could unlink from the archive.
  13. Fixed an issue which caused automatic restart of the Self-diagnostics Service after its incorrect shutdown.
  14. Fixed an issue with the Self-diagnostics Service after changing the server name.
  15. Fixed a rare issue with positioning during archive playback.
  16. Fixed an issue which caused reset of some events (relay triggers) on the Event Board after changing the layout.
  17. Fixed an issue with positioning during archive playback if there were detection tools.
  18. Fixed fonts in Korean localization.
  19. Fixed AxxonNext.exe crash when exporting if H.264 video codec and AAC audio codec both were in the exported file.
  20. Fixed issues with hardware decoding for videos created using YUV422 format.
  21. Fixed a rare issue which caused client crash when saving a modified layout.
  22. Fixed a rare issue due to which AxxonNext.exe would not run.
  23. Fixed a rare issue due to which used licenses were not displayed.
  24. Fixed an issue due to which the masking was not saved when editing a layout.
  25. Fixed automatic connection in failover cluster mode.
  26. Fixed an issue due to which the camera in immersive mode was not centered.
  27. Fixed an issue with --copy command execution in Vfs_tools utility on Linux.
  28. Fixed a rare issue with collecting system information in the Support utility on Linux.
  29. Fixed a rare issue due to which frames from one camera glimpsed in the archive view mode of another camera.
  30. Fixed an issue with the license if there were video recorders in the key.
  31. Fixed an issue due to which an archive for automatic updates was created even if the "Create an archive for automatic update" checkbox was disabled.
  32. Fixed an issue with the "Show camera" macro operation when upgrading from older versions of Axxon Next.
  33. Fixed an issue with configuration loading if there was a camera with a name containing a special character.
  34. Fixed an issue due to which an authorized Web client user was blocked if there were unsuccessful attempts to log in using the same user account on another Web client.
  35. Fixed an issue due to which the selected alarm would not open from the Alarms panel.
  36. Removed the third-party VideoLan player (vlc.exe) from the distribution package.
  37. Updated localization for Hungarian, Korean, Farsi, Polish, Danish, Czech, Chinese.

IP device support

The release includes Drivers Pack 3.71 for IP devices support (see Release Notes Drivers Pack 3.71).

Analytics

The release includes the Axxon Next DetectorPack 3.6.0 drivers package (see DetectorPack 3.6.0 Release Notes). 

Downloads and licensing

The Axxon Next installer includes both the client and server components. The client can be installed on a computer together with the server, or installed on a separate dedicated client workstation. There is no limit on the total number of servers and clients in a system.

5 Axxon Next license types are available: demo mode with limited operating hours, free version and 3 types of paid licenses (Start, Professional and Universe). Data on all the types of Axxon Next licenses is given on the page.

Free version supports 1 server, 4 video streams, unlimited archive as well as unlimited number of clients.

Updating from previous versions

Please update to 4.5.10 version from 4.4.6 version or 4.5.0-4.5.8 version. To do this, run the installer of the new version and select the existing configuration during the installation. Deinstallation of the previous version is not required.

If you have an earlier version installed, please perform a step-by-step upgrade: 3.6.4. → 4.1.0 → 4.3.2 → 4.4.6 → 4.5.10.

When upgrading from 4.4.6, please note the following:

In Axxon Next 4.5.0, the system log database format is changed and its size is increased. When you update from a previous version, the existing database will be converted.

Before the update starts, the free space on the disk where the database is located will be checked. If the free disk space is less than four times the size of the current database, a window will be displayed with a warning that some of the events may be lost.

Immediately after the update, you need to adjust the database storage settings (see Configuring storage of the system log and metadata) and/or increase the free disk space.

After update to 4.5.10 version, it is necessary to reconfigure all filters for the Events boards (see Configuring Events Boards).


Product documentation

System Requirements

Axxon Next Installation Guide

Axxon Next Activation Guide

Axxon Next Quick Start Guide

Complete Axxon Next Documentation

  • No labels