Documentation for Auto PSIM 1.0.1.

Previous page Setting up ports for notification and xml notification  The Traffic Monitor interface object setup Next page

Auto PSIM and Axxon One can operate together. The joint operation allows you to:

  • receive video from the Axxon One cameras for further license plate recognition using the Auto PSIM license plate recognition modules;
  • receive events about the license plate recognition as from an external recognizer.

Attention!

Auto PSIM and Axxon One must be located on the same Server.

Set up the joint operation of Auto PSIM and Axxon One as follows:

  1. Make sure that the port for connecting to Axxon One specified in the An.port registry key is 20111 (see Registry keys reference guide, for details about working with the registry, see Working with Windows OS registry).
  2. Create and configure the NGP manager module for connecting to Axxon One (see the details on configuration of this module in the Axxon PSIM. Administrator's Guide, the most current version of the document is located in the AxxonSoft documentation repository). As a result, the objects of the corresponding Axxon One cameras will be automatically created in Axxon PSIM.

    Note

    To ensure the correct connection, Axxon One must be launched with administrator rights.

    Once the joint operation of Axxon PSIM and Axxon One is enabled, the creation of Video capture device objects becomes unavailable.

  3. If it is necessary to recognize the license plates using the Auto PSIM license plate recognition module, then Auto PSIM must be configured in a standard way, and the appropriate Axxon One camera must be selected on the settings panel of the LPR channel object (see Selecting the video cameras to work with the LPR channel).
  4. If the license plates are recognized on the Axxon One side, then in order to receive the license plate recognition events as from an external recognizer, it is necessary to activate the Remote recognition module.
  5. To view the video archive by the event from the video camera which is used for the license plate recognition, select AxxonOne monitor on the settings panel of the Vehicle Tracer object (see Selecting the Monitor object for playing back the video archive).

Setting up the joint operation of Auto PSIM and Axxon One is now complete.

  • No labels