Parameter name | Field type | Description | Data type | Default value | Value range | |
---|---|---|---|---|---|---|
1 | Camera | List | Selecting the camera to work together with the Auto-Uragan module | List of available Camera objects | Not specified | Depending on the number of available Camera objects |
2 | Speed limit | Enter the value in the field | Entering the permitted vehicle speed on the controlled area for displaying in the report concerning the recognized number. | Km/h | - | Unlimited |
3 | Alarm on speed limit | Text field | Entering the maximum allowed vehicle speed the exceeding of which leads to the alarm registration | Km/h | - | Unlimited |
Speed-trap group | ||||||
4 | Target | List | Driving direction of the vehicle to be recognized | List of available directions | Oncoming | Oncoming – vehicles driving toward the speed-trap |
Distance | List | Setting an approximate distance between the speed-trap and the vehicles to be recognized | List of available distances | Small | Small | |
Model | List | Selecting the speed-trap model | List of integrated speed-trap devices | - | Berkut | |
Type | List | Specifying the type of the speed-trap installation | List of installation paramaters of the speed-trap devices | Stationary | Stationary – the speed-trap is static | |
Port settings group | ||||||
5 | Port | List | COM-port number | List of available COM-ports | COM1 | Depending on the system configuration |
Speed-trap configuration group | ||||||
6 | Installation angle, * | Text field | The angle of the speed-trap installation in relation to the horizon | Degrees | Not specified | 0 - 360 |
Detection threshold, km/h | Text field | Minimum speed detectable by the speed-trap | Km/h | Not specified | Unlimited | |
7 | Address | Enter the value in the field | Set the address of speed-trap position | - | - | - |
ID | Enter the value in the field | Set the factory ID number of speed-trap device | - | - | Depends on the producer of the device | |
Certificate | Enter the value in the field | Set the number of the certificate, correspondidng to speed-trap device | Number | - | - | |
Checking valid till | Select from the listcalendar is used) | Set the date until which verification is valid | Date in format: | Current date | - |