Purpose of Axxon One + ACFA + ACS/FSA/PID equipment integration
- Provide user interface within different subsystems of security equipment in one software.
- Set up cause-and-effect relations between different subsystems (video surveillance, FSA, ACS, and so on).
- Use network capability of the software.
- Joint marketing promotion of integrated solutions by manufacturers of software and equipment.
Integrated equipment
Designation in the table | Description |
---|---|
Functionality | |
Monitoring | Integration module only allows you to receive events. Control and configuration from Axxon One + ACFA is impossible |
Monitoring, control | Integration module allows you to receive events and control objects, for example, from a map: arm/disarm alarm loops, command actuating devices, and so on. Configuration from Axxon One + ACFA is impossible |
Monitoring, control, configuration | Integration module allows you to perform any operations (equipment configuration, control, monitoring) using only Axxon One + ACFA |
Auto configuration | Integration module allows you to read configuration from equipment and build the corresponding object tree in Axxon One + ACFA |
Licensing | |
ACFAReader | Module type in ACFA Reader price list |
ACFASensor | Module type in ACFA Sensor price list |
ACFAFence | Module type in ACFA Fence price list |
Type of integration | |
Low-level protocol | System developer has provided events, reactions, commands as a set of bytes for connection to the equipment, so the equipment can be directly connected to Axxon One + ACFA |
SDK | Software Development Kit. System developer has provided an SDK, so the equipment can be directly connected to Axxon One + ACFA |
Communication server | Driver program. System developer has provided their own driver (a software layer between AxxonSoft software and the equipment in which events, reactions, configuration commands, and status polling are embedded) for connecting the equipment. In order to connect the equipment to Axxon One + ACFA, you must install third-party service software and configure its interaction with Axxon One + ACFA. COM server and OPC server are examples of such programs |
API | Application Programming Interface. System developer has provided an API for working with the equipment via the Web-server embedded into the equipment, so the equipment can be directly connected to Axxon One + ACFA |
SOFT-SOFT | System developer has provided an API to enable the use of your commands in Axxon One + ACFA and the Axxon One + ACFA commands in your software. In order to connect the equipment to Axxon One + ACFA, you must install the full version of the third-party software and configure its interaction with Axxon One + ACFA. Database synchronization is a variant of SOFT-SOFT type of integration at the level of sharing one database between two software, for example, for access to Event Viewer Note For SOFT-SOFT type of integration, the equipment connection interface isn't specified, since Axxon One + ACFA isn't connected directly to the equipment, but to third-party software. We recommend you to contact the manufacturer of such software to specify the equipment connection interface. |
Universal protocol | Universal protocol integration:
|
Drivers Pack | Integration by one of the above methods via Drivers Pack. When you use this type of integration, you must install Axxon One, ACFA, and Drivers Pack to work with the equipment |
Name of the integration module | Integrated software, hardware | Functionality | Licensing | Information on manufacturer | Type of integration | Hardware connection interface | ACFA version |
---|---|---|---|---|---|---|---|
ACS integration modules | |||||||
AXIS: A1001 | Axis A1001 | Monitoring, control | Per each access point (ACFAReader) | Axis Communications AB Address: Schweden, Lund, Phone: +46 46 272 18 00 Fax: +46 46 13 61 30 Website: www.axis.com | API | Ethernet | 2.0 |
Dormakaba: Keyscan Aurora | Keyscan Aurora version 1.0.24.0 | Monitoring, control | Per each reader (ACFAReader) | dormakaba Canada Inc Address: 901 Burns St., E. Whitby, Ontario, Canada L1NOE6 Phone: 888-539-7226 Website: www.dormakaba.us Email: eadorders.ca@dormakaba.com | SOFT-SOFT | NA | 1.0 |
SALTO: ProAccess SPACE | SALTO ProAccess SPACE version 6.10.3.1 | Monitoring, control | Per each:
| SALTO Systems, S.L Address: Pol. Lanbarren C/ Arkotz, 9 Phone: +34 943 344 550 Website: www.saltosystems.com | SOFT-SOFT | NA | 1.0 |
ZKTeco: PUSH SDK | All ZKTeco access control devices that work via the PUSH SDK protocol (SpeedFace, ProFace, ELITE PASS terminals and Inbio Pro, C2-260, and so on controllers) are integrated | Monitoring, control | Per each door (ACFAReader) | ZKTeco Address: ZK Building, Wuhe Road, Gangtou, Bantian, Buji Town, Longgang District, Shenzhen, China Phone: +86 755-33985019 Fax: 12 39 89 901 Website: www.zkteco.com Email: service@zkteco.com | SDK | Ethernet | 1.0 |
Sigur: Sigur server | Sigur software versions 1.1 and 1.6 | Monitoring, control | Per each access point (ACFAReader) | PA Labs d.o.o. Address: Zemljemerska, 12, 1000 Ljubljana, Slovenia Phone: +7 (831) 433-32-82, +7 (831) 462-30-74 Website: www.sigur.com Email: sales@sigur.com, support@sigur.com | SOFT-SOFT | NA | 1.0 |
Suprema: BioStar 2 server | BioStar 2 software versions 2.9.4 and 2.9.5 | Monitoring, control | Per each device (ACFAReader) | Suprema Inc. Address: 17F Parkview Office Tower, Jeongja, Bundang, Seongnam, Gyeonggi, 463-863 Republic of Korea Phone: +82 31 783 4502 Website: www.supremainc.com | SOFT-SOFT | NA | 1.0 |
Vauban: Visor | Vauban VISOR® | Monitoring, control | Per each:
| Vauban Systems Address: Vauban Systems – Parc d’Activités Saint Christophe 7, rue du petit Albi Phone: +33 (0)1 30 27 25 35 Hotline: +33 (0)1 30 27 92 69 Fax: + 33 (0) 1 30 27 21 72 Website: www.vauban-systems.fr Email: contact@vauban-systems.fr | API | Ethernet | 2.0 |
FSA integration modules | |||||||
RISCO: ProSYS Plus | All models of the ProSYS™ Plus Main Board series. Сharacteristic:
| Monitoring, control | Per each zone (ACFASensor) | RISCO LTD Address: Israel, 75655 Rishon LeZion, 14 Hachoma Street Phone: +972-3-9637777 Fax: +972-3-9616584 Website: www.riscogroup.com Email: info@riscogroup.com Sales department: sales@riscogroup.com | Low-level protocol | Ethernet | 1.0 |
Rozetatech: Obelisk | Rozetatech OBELISK-1.0 Gateway | Monitoring, control | Per each device (ACFASensor) | Rozetatech Co Ltd Address: B-1710, 2nd Woollim Lions Valley.14, Sagimakgol-ro 45beon-gil, Jungwon-gu, Seongnam-si, Gyeonggi-do Phone: +82-31-736-5308 Website: www.rozetatech.co.kr Email: contactus@rozetatech.co.kr | SOFT-SOFT | NA | 1.0 |
Satel2 ETHM-A | Satel2 ETHM-A | Monitoring, control | Per each:
| SATEL sp. z o.o. Address: Budowlanych 66, 80-298 Gdansk, Poland Phone: +48 58 320 94 00 Fax: +48 58 320 94 01 Website: www.satel.pl Email: satel@satel.pl | Low-level protocol | Ethernet | 1.0 |
Satel2: Panel |
| Monitoring, control, configuration | Per each:
| SATEL sp. z o.o. Address: Budowlanych 66, 80-298 Gdansk, Poland Phone: +48 58 320-94-00 Fax: +48 58 320-94-01 Website: www.satel.pl Email: satel@satel.pl | Low-level protocol | Ethernet | 1.0 |
UniPOS: 7000 | All interactive fire control panels of the 7000 series are integrated | Monitoring, control, configuration | Per each:
| Unipos Address: Sofia, Bulgaria, Mladost 1, 1 Efr. Nikola Paskalev Str., next to block 56 Phone: + 359 2 97 444 69 Website: www.unipos-bg.com Email: office_sofia@unipos-bg.net | Low-level protocol | RS-232 | 1.0 |
PID integration modules | |||||||
Vanderbilt: SPC panel |
| Monitoring, control | Per each zone (ACFASensor) | ACRE Security Website: acresecurity.com | Low-level protocol | Ethernet | 1.0 |
DEA: FUSION P2P | BR-FSP2PLT-CTRL | Monitoring, control | Per each:
| DEA Security Phone: +39 0187 699233 Fax: +39 0187 697615 Website: https://www.deasecurity.com/en/ Email: dea@deasecurity.com, | Low-level protocol | Ethernet | 2.0 |
Name of the integration module | Functionality | Licensing | Type of integration | ACFA version |
---|---|---|---|---|
General purpose protocols integration modules | ||||
Modbus master | Module can exchange data, receive events and send commands via Modbus TCP or Modbus RTU protocols | Per each register (ACFASensor) | Universal protocol (Modbus) | 2.0 |
OPC DA Wrapper | Module can transfer data in real time and integrate systems with different interfaces, providing centralized monitoring and process control | Per each variable (ACFASensor) | Universal protocol (OPC) | 1.0 |
OPC UA | Module is used to connect to OPC server and can exchange data and receive events according to UA standard | Per each:
| Universal protocol (OPC) | 2.0 |
SNMP Agent | Module can exchange data and receive events via SNMP protocol v.1, v.2 and v.3 | Per each SNMP value (ACFASensor) | Universal protocol (SNMP) | 2.0 |
Name of the integration module | Functionality | Licensing | ACFA version |
---|---|---|---|
Service integration modules | |||
MQTT Broker | The MQTT broker integration module is part of ACFA and serves as an optional feature for ACFA integrations that use the MQTT protocol. Its presence eliminates the need to install third-party MQTT Broker applications, which simplifies the integration process and improves usability. This module doesn’t send events to any interfaces and has no control commands | Module isn't licensed | 1.0 |
ActiveMQ broker | Module is used to connect devices that use it for operation. Apache ActiveMQ is the most popular multiprotocol message broker with open source code, based on Java. Apache ActiveMQ translates messages from sender to receiver. It can connect multiple clients and servers and allows storing messages in a queue, rather than requiring both client and server to be available at the same time for communication. Such message brokers are often used in enterprise systems or any systems with a complex architecture | Module isn't licensed | 2.0 |
Emulator ACFA | Module can perform the following actions:
| Per each:
| 1.0 |