Documentation for Intellect 4.10.4. Documentation for other versions of Intellect is available too.

Previous page Selecting disks for storing the archive of the Videogate module  Notification services Next page


By default, if disks are selected for storing the archive of the Videogate module (see Selecting disks for storing the archive of the Videogate module), then Videogate requests video streams for all selected cameras (see Selecting and configuring the cameras for the Videogate module) from Server and only records the Videogate module archive if recording is configured for these cameras on the Server. Continuous Videogate archive record by all added cameras regardless of Server configuration, as well as record only on cameras requested on clients can be enabled.

To configure the record of the Videogate module archive do the following:

  1. Go to the Videogate object settings panel.
  2. If continuous record on all cameras added to the Videogate is required regardless of whether the Server records its archive or not, set the Constant recording checkbox (1).
  3. If only cameras requested on clients (i.e. displayed in the Video surveillance monitor) are to be recorded to the Videogate module archive, set the Active cameras recording checkbox (2).
  4. Click Apply (3).

Configuring the record of the Videogate module archive is completed.