The “GAI-Tronics HelpPoint” SIP-device is configured through the Web-interface the following way:
- Change IP-address of SIP-device on the “IP Settings” tab if it’s needed;
Specify parameters of SIP protocol on the “SIP Settings” tab.
№
Parameter
Parameter value
Information
1
LOCALID
Sequence of symbols (letters, digits etc.)
User ID for connecting to the SIP-device
2
PROXY
Empty field
Proxy-server is not in use
Call from the SIP-device readdresses directly to the Intercom Subsystem Server
3
REGISTRAR
Empty field
Readdress Server is not in use
4
USERNAME
Sequence of symbols (letters, digits etc.)
User name of SIP-device. Should coincide with “LOCALID” parameter value
5
PASSWORD
Sequence of symbols (letters, digits etc.)
Password to connect to the SIP-device
6
ENDPOINT
ENABLED
SIP-device activated
Add the Intercom Subsystem Server of security intercom terminals to the contact list of SIP-device on page 1 «Memories & Comfort Strings» of the «Dialing & Memories» tab.
№
Parameter
Parameter value
Information
1
MEMORY
sip:<name>@<IP address>
SIP URL consists of two parts:
<name> -user name. It is ignored while calling
<IP address> - IP-address of Intercom Subsystem Server
2
COMFORT
Sequence of numbers
Use to configure calls addressing from SIP-device (see step 4)
Set the call direction while clicking the call button on page 2 «Memory Lists» of the «Dialing & Memories» tab.
№
Parameter
Parameter value
Information
1
Number
Sequence of numbers
Number of required call button
2
WAKEANDIAL
ON
Includes the call addressing to the Intercom Subsystem Server while clicking the required button
3
LIST
Sequence of numbers
Should coincide with “COMFORT” parameter value, corresponding to the SIP URL of required Intercom Subsystem Server (see step 3).
Configuring of the «GAI-Tronics HelpPoint» SIP-device through the Web-interface is completed.