Configure the main parameters of the Incident manager as follows:
- Go to the the Main tab of the Incident manager object settings panel.
- In the Incident servers window, set the checkboxes next to those Incident server and Incident handler objects, the events and processing logic from which will be displayed in the interface (1) (see Configuring Incident server and Incident handler).
- If necessary, set a hotkey, using which the operator can start processing the event. To do this, place the mouse cursor in the "In work" hotkey field (2) and press the required key or key combination on the keyboard.
- From the Map drop-down list (3), select the previously created Map object, which will be linked with the Incident manager. The operator can make the object with the event be highlighted on the map.
- From the Video drop-down list (4), select a video display mode:
- ActiveX - archive and live video will open in a separate window.
- Monitor - archive and live video will open on the selected Surveillance Monitor. In this case, the Surveillance Monitor will operate in the Active camera mode, regardless of the corresponding setting - see Configuring the display mode of camera windows.
- In the Maximum number of online events field (5), set the maximum number of events that can be simultaneously displayed in the interface. The default is 10 (minimum value), the maximum value is 5000.
- Click the Apply button (6).
The the main parameters of the Incident manager are configured.