Go to documentation repository
Documentation for Intellect 4.11.0-4.11.3. Documentation for other versions of Intellect is available too.
When changing the ddi file events, reactions, etc. can be added, modified or deleted.
To reduce database load modify the intellect.ddi file as follows:
- Open the intellect.ddi file in the ddi.exe utility.
- Select the CAM object.
- Go to the Events tab.
- Set the Do not record and Do not send to the network checkboxes checked for the MD_START (Alarm) and MD_STOP (Alarm end) events.
Save the file.
Update the database using the idb.exe utility (the Update database button, see Interface elements of the idb.exe window).
When these actions are performed the events from the main motion detection tool are not recorded and sent to other cores. This reduces the database load.
Important!
When updating Intellect the modified intellect.ddi file is substituted with the file by default.
In order the intellect.ddi file is not substituted it is to be saved with another name at step 5 - e.g. "intellect_1.ddi". Thus, 2 files of external settings are saved in the Languages catalog: source file and modified one. The idb.exe utility loads them in alphabetical order. As a result the intellect_1.ddi file is loaded the last one and its parameters are applied when database is updated.
If the event list in intellect_1.ddi is different from the original intellect.ddi, e.g. some events are added or deleted, then the event list is merged by idb.exe DB update.
When installing a new Intellect version the intellect_1.ddi file is not affected by the installation wizard and changes are saved.
Important!
When deleting Intellect without saving the configuration the entire Intellect catalog (including modified files) is deleted. In this case the modified files are to be manually backed up, e.g. to C:\Temp, ander after reinstallation they are to be copied to <Intellect installation folder>\Languages\ru.