Go to documentation repository
Documentation for Intellect 4.11.0-4.11.3. Documentation for other versions of Intellect is available too.
Configuring Lilin PIH-800III telemetry control panel
Configure the Lilin PIH-800III telemetry control panel in the Intellect as follows:
- Create the Telemetry controller object.
- Configure the Telemetry controller object as follows:
Specify the Lilin PIH-7000/7600 communication protocol.
Note.
In order to transmit directly data to Lilin cameras connected via a serial port, select the Lilin PIH-7000/7600 Direct communication protocol. However, the full functionality of these cameras can be used, even what is not supported by Intellect.
- In the Port list specify the number of the serial (COM) port for connecting to the telemetry controller.
- Specify 9600 value for the Speed parameter.
- Specify None value for the Parity parameter.
- Set the DTR and RTS checkboxes checked.
- Create the Control panel object under the Telemetry controller object.
- Configure the Control panel object as described in Telemetry control panel configuration section.
Lilin PIH-800III telemetry control panel is now configured in Intellect.
Using Lilin PIH-800III telemetry control panel
Some of Lilin PIH-800III telemetry control panel's keys correspond to standard functions in Intellect.
Note.
The functionality of these keys is also described in the reference documentation on Lilin PIH-800III control panel.
Key | Function |
ZOOM IN / ZOOM OUT | Increases/decreases the size of the image |
FOCUS FAR / FOCUS NEAR | Increases/decreases the focal distance of the lens |
IRIS O / IRIS C | Opens/closes the aperture |
AUTOFOCUS | Sets the focal distance of the lens automatically |
AUTOIRIS | Automatically selects the position of the aperture |
AUTOPAN | Switches the pan head to auto-pan mode; or switches a dome camera to auto-patrol mode |
PRESET | Switches to a preset; saves a preset |
PRESET 1/2/3/4 | Switches to preset 1/2/3/4 |
Some of Lilin PIH-800III control panel's keys can be used through the KEY_PRESSED event. Intellect receives the KEY_PRESSED event when these keys are pressed on Lilin PIH-800III telemetry control panel's keyboard.
Event | Message | Parameter | Description |
KEY_PRESSED | A key was pressed | param0 | Code the key that was pressed |
The source of this event is the Control panel object (TELEMETRY_EXT). The event's documentation indicates the code of the key that was pressed (param0). The key code for entering a number (1, 2, or 4 digits) is equal to the number entered. A four-byte hexadecimal code is used for function keys.
Key | Code | Hexadecimal code |
ESC | 1769472 | 0x001B0000 |
LIGHT | 655360 | 0x000A0000 |
CTRL1 | 851969 | 0x001A0000 |
CTRL2 | 851970 | 0x00090000 |
CLR | 3604480 | 0x00370000 |
ENT | 3538944 | 0x00360000 |
WIPER | 786432 | 0x000C0000 |
SPRAY | 720896 | 0x000B0000 |
No messages are sent to Intellect when the F1-F4, MON and CAM keys are pressed.
Control panel functions associated with the execution of actions in Intellect when events arrive from the control panel can be implemented using the following resources:
- Scripts written in the JScript programming language (see The Script object. Programming using the JScript language for more information on how to create scripts);
- programs written in internal programming language in Intellect;
- macros (see Creating and using macros in Administrator's Guide for more information).