Configure Samsung SSC-2000 telemetry control panel in Intellect as follows:

  1. Create the Telemetry controller object.
    1. Configure the Telemetry controller object as follows:
    2. Specify the Samsung communication protocol.

    3. In the Port list, select the number of the serial (COM) port for connecting to the telemetry controller.
    4. Specify 9600 value for the Speed parameter.
    5. Specify None value for the Parity parameter.
    6.  Set the DTR and RTS checkboxes checked.
  2. Create the Control panel object under the Telemetry controller object.
  3. Configure the Control panel object as described in Telemetry control panel configuration section.

Samsung SSC-2000 telemetry control panel is now configured in Intellect.