New features in build 4.11.3.4084

A number of improvements were made to increase the stability of the system.

New features in Intellect 4.11.3

  1. Added UPDATE_ESCALATE_STATUS command to Incident manager. The command can be used in scripts for escalating the specified events.

  2. Added a new SCRIPT_ERROR event for the SLAVE object. This event is generated if the script execution fails.

  3. Optimized system performance when the MemFile registry key value is set to -1 (default):

    1. now the statistics displays the buffer size for writing, the limit of which is set in the WriteBufferSize parameter;

    2. added the FileSystem.PreAllocateFileSize parameter, which sets the minimum size of the created temporary file in MB;

    3. added the FileSystem.WriteBufferMemoryLimit parameter, which sets the maximum possible size of the RAM buffer in MB for the channel before the data from the buffer is written to the archive.
      These improvements are made so that frames are not skipped when recording to archive under high system load

  4. For the request API for receiving video subsystem events http://IP-address:port/web2/secure/events/ added the ability to specify several objects separated by commas in the objectId parameter, and to receive all triggers from objects of the same type.

  5. For the MAP object, added the layer parameter to the ACTIVATE_OBJECT event — it is the identifier of the layer on which the event occurred.

  6. Updated the Incident handler: now when you select the events for display and processing, you can select any camera events, not just alarms.

  7. In the Monitor object, added a column with a unique camera identifier (Guid) to the table of the Camera list tab.

  8. It is now possible to use an external database for the Incident Server

  9. In the Incident manager, updated the Last comment and All comments columns: now only the first line of the comment is displayed in them, and the full comment is displayed in the tooltip.

  10. Now you can minimize the Events protocol interface window on the screen. To do this, set the value 1 to the new ShowInTaskbar registry key.

IP device support

The release includes Drivers Pack 3.73.85 for IP devices support. Detailed information about the Drivers Pack, where to find the latest set of drivers, and the list of supported hardware is available at https://www.axxonsoft.com/integrated_security_solutions/supported-ip/

Updating from previous versions

Run the newer version installation program and install Intellect over the older version 4.11.2 or earlier. No need for uninstalling.

Product documentation

Requirements for base PCs

Updating INTELLECT™ software